Laserfiche WebLink
Table 4. Assumptions for Nitrate Loading Calculation <br /> Variable Value Units Description <br /> Q 350 gpd Effluent flow rate <br /> Nw 35 mg/L-N Effluent stream concentration <br /> A 3.57 acres Site area <br /> Nb 0.17 mg/L-N Concentration of rain <br /> d 0.35 constant Denitrification factor <br /> R 3.23 inches per year Recharge rate of rainfall <br /> W 1.3 inches per year Uniform waste water loading (calculated) <br /> The details of the nitrate loading calculation are included in Plate 13. The results of the <br /> calculation are presented in the following table. <br /> Table 5. Result of Nitrate Loading Calculation <br /> Variable Value Units Description <br /> Nc 6.7 mg/L-N Long-term average concentration of percolating effluent <br /> The US EPA recommended MCL for nitrate in drinking water is 10 mg/L-N. In a worst- <br /> case situation, the maximum buildup of nitrates in the aquifer from the use of septic <br /> systems on the Site is predicted to be 6.7 mg/L-N. The result of the nitrate loading <br /> estimate is less than the maximum drinking water standard. <br /> Discussion of Nitrate Loading Results <br /> Total Nitrate Impact <br /> Based on the method and assumptions described, the result of the nitrate loading <br /> estimate indicates that the proposed development on the Site should not cause a <br /> buildup of nitrates in the aquifer over 10 mg/L-N. Because of the favorable result of the <br /> nitrate loading calculation, no nitrate mitigation is recommended at this time. <br /> LOGE 2122 Page 12 <br />