P
>
PADDY CREEK
>
12938
>
2600 - Land Use Program
>
SR0083677_SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2021 8:25:58 AM
Creation date
5/21/2021 3:02:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SR0083677
PE
2602
FACILITY_NAME
CARROLL PROPERTY
STREET_NUMBER
12938
Direction
N
STREET_NAME
PADDY CREEK
STREET_TYPE
LN
City
LODI
Zip
95240
APN
06317005
ENTERED_DATE
5/7/2021 12:00:00 AM
SITE_LOCATION
12938 N PADDY CREEK LN
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
rate for a shallow test is greater than or equal to 1 minute per inch (min/in) but less than <br /> or equal to 60 min/in drop. A deep percolation test hole has a depth between 3.5 and <br /> 25 feet; a satisfactory percolation rate for a deep test is greater than or equal to 1 min/in <br /> but less than or equal to 30 min/in drop. For the Site to utilize a standard septic system, <br /> one percolation test hole (shallow or deep) must demonstrate a satisfactory percolation <br /> rate within the proposed septic system disposal field. <br /> Details and results of the percolation testing are summarized in the following table. <br /> Table 2. Percolation Test Summary <br /> Test No., Percolation Test Percolation Rate Test Duration Comments <br /> Date Tested Depth (ft.) (minutes/inch) (see notes) <br /> P1-S, Insufficient perc. <br /> 4/27/2021 3.29 250 4 hr. <br /> Shallow Test rate* <br /> P1-D, Satisfactory <br /> 2/9/2021 6.31 27.8 4 hr. perc. <br /> Deep Test rate <br /> Note: A satisfactory percolation rate for a "shallow" test is greater than 1 but less than or equal to 60 minutes per <br /> inch. A satisfactory percolation rate for a "deep" test is greater than 1 but less than or equal to 30 minutes <br /> per inch. <br /> Only one percolation test boring (shallow or deep) is required to pass for the property to be approved for a <br /> standard septic system. <br /> Discussion of Percolation Test Results <br /> The soils within the proposed sewage disposal area of the Site have demonstrated a <br /> satisfactory percolation rate for the use of a standard septic system in accordance with <br /> the requirements of the San Joaquin County Environmental Health Department. The <br /> percolation test is considered representative of soils within a 100-foot radius of the test <br /> location. <br /> Discussion of Septic System Sizing <br /> Septic system construction utilizing leach lines with seepage pits should follow the San <br /> Joaquin County On-Site Wastewater Treatment Systems Standards (2017) where <br /> applicable. <br /> LOGE 2125 Page 7 <br />