My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
FIELD DOCUMENTS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WELTY
>
35500
>
4800 – General/Other Program
>
PR0508043
>
FIELD DOCUMENTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2021 11:19:37 AM
Creation date
5/24/2021 10:29:31 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4800 – General/Other Program
File Section
FIELD DOCUMENTS
RECORD_ID
PR0508043
PE
2960
FACILITY_ID
FA0007905
FACILITY_NAME
CHEVRON PIPELINES
STREET_NUMBER
35500
STREET_NAME
WELTY
STREET_TYPE
RD
City
VERNALIS
Zip
95385
APN
25526003
CURRENT_STATUS
01
SITE_LOCATION
35500 WELTY RD
P_LOCATION
99
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
350
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix A:Previous Environmental Activities <br /> petroleum-hydrocarbon plume sourced from one or both of the two petroleum pipelines located <br /> approximately 34 feet northeast of the Hunter Container building, and owned by Southern <br /> Pacific Pipeline Company and Chevron. Geological Technics recommended that"San Joaquin <br /> County and RWQCB work with the two pipeline companies to address the petroleum <br /> hydrocarbon issue." <br /> RADIAN INTERNATIONAL,LLC (RADIAN) 1997 GROUNDWATER <br /> INVESTIGATION <br /> On February 27, 1997, Radian was contracted by CPL to conduct a limited groundwater <br /> investigation at the Hunter Container property to determine if TCE had affected the groundwater. <br /> Radian advanced three cone penetration test(CPT)borings (CPT-1, CPT-2, and CPT-3),and <br /> groundwater samples were collected at two distinct intervals(35 and 50 feet bgs) and tested by <br /> an analytical laboratory. TCE was not detected in any sample. Cis-1,2-dichloroethene, a <br /> degradation product of TCE, was detected in one of the groundwater samples at a concentration <br /> below the United States Environmental Protection Agency(EPA)Maximum Contaminant Level <br /> (MCL) for drinking water. Radian concluded that"TCE and other chlorinated organic <br /> hydrocarbons have not impacted groundwater." <br /> RADIAN 1998 SITE INVESTIGATION' <br /> In July 1998, six soil borings(B-1 through B-6)were advanced at Hunter Container and three <br /> monitoring wells (MW-2, MW-3, and MW-4)were installed. TPHg,TPHd, and TPHmo were <br /> detected in borings B-1, B-4, B-5, B-6, and monitoring well MW-2. Elevated concentrations of <br /> TPHg(1,400 mg/kg)were detected in B-5 at 10 feet bgs, and TPHd(21,000 mg/kg) and TPHmo <br /> (15,000 mg/kg)were also detected in B-5 at 20 feet bgs. Laboratory analytical results indicated <br /> TPHd concentrations of 2,300 and 300 µg/L in wells MW-2 and MW-3, respectively, and a <br /> TPHmo concentration of 700 µg/L in MW-2. No other constituents of potential concern <br /> (COPCs) were detected in groundwater samples. <br /> GEOMATRIX CONSULTANTS,INC. (GEOMATRIX) 2000 SOIL AND <br /> GROUNDWATER INVESTIGATIONS <br /> On November 9 through 11, 1999, at the request of Chevron Environmental Management <br /> Company(CEMC), Geomatrix advanced seven soil borings(GMX-1 through GMX-7)to assess <br /> the vertical and lateral extent of affected soil and groundwater. Borings GMX-6 and GMX-7 <br /> were advanced off site, on the east side of Highway 33. Additionally, groundwater samples were <br /> collected from monitoring well WFSMW-1 on the Western Farm Service(now Crop Production <br /> Services [CPS])property and tested for the COPCs. The investigation also evaluated the <br /> presence of TCE in site soil at the request of the Central Valley Regional Water Quality Control <br /> Board(RWQCB). <br /> TPH quantified as crude oil(TPHc)was detected in soil at a concentration of 10,000 mg/kg at <br /> 37 feet bgs from GMX-3, and polynuclear aromatic hydrocarbons(PAHs) were detected at <br /> concentrations ranging from 0.007 to 0.55 mg/kg. <br /> 6. Radian,1997. 27 February 1997 Groundwater Sampling at 35275 Welty Road, Vernalis, California. March. <br /> 7. Radian,1998. Site Investigation at 35275 Welty Road, Vernalis, California. <br /> 8. Geomatrix,2000. Soil and Groundwater Investigation Report,35275 Welty Road,APN 255-180-09, Vernalis,California. <br /> February. <br /> A-3 SAIE <br />
The URL can be used to link to this page
Your browser does not support the video tag.