Laserfiche WebLink
tiff e u rof i n s Lancaster <br /> Laboratories Explanation of Symbols and Abbreviations <br /> P Y <br /> The following defines common symbols and abbreviations used in reporting technical data: <br /> RL Reporting Limit BMQL Below Minimum Quantitation Level <br /> N.D. none detected MPN Most Probable Number <br /> TNTC Too Numerous To Count CP Units cobalt-chloroplatinate units <br /> IU International Units NTU nephelometric turbidity units <br /> umhos/cm micromhos/cm ng nanogram(s) <br /> C degrees Celsius F degrees Fahrenheit <br /> meq milliequivalents Ib. pound(s) <br /> g gram(s) kg kilogram(s) <br /> pg microgram(s) mg milligram(s) <br /> mL milliliter(s) L liter(s) <br /> m3 cubic meter(s) pL microliter(s) <br /> pg/L picogram/liter <br /> < less than-The number following the sign is the limit of quantitation, the smallest amount of analyte which can be <br /> reliably determined using this specific test. <br /> > greater than <br /> J estimated value—The result is>_the Method Detection Limit(MDL)and <the Limit of Quantitation (LOQ). <br /> PPM parts per million-One ppm is equivalent to one milligram per kilogram (mg/kg), or one gram per million grams. For <br /> aqueous liquids, ppm is usually taken to be equivalent to milligrams per liter(mg/1), because one liter of water has a <br /> weight very close to a kilogram. For gases or vapors, one ppm is equivalent to one microliter of gas per liter of gas. <br /> ppb parts per billion <br /> Dry weight Results printed under this heading have been adjusted for moisture content. This increases the analyte weight <br /> basis concentration to approximate the value present in a similar sample without moisture. All other results are reported <br /> on an as-received basis. <br /> U.S. EPA CLP Data Qualifiers: <br /> Organic Qualifiers Inorganic Qualifiers <br /> A TIC is a possible aldol-condensation product B Value is<CRDL, but>_IDL <br /> B Analyte was also detected in the blank E Estimated due to interference <br /> C Pesticide result confirmed by GC/MS M Duplicate injection precision not met <br /> D Compound quantitated on a diluted sample N Spike sample not within control limits <br /> E Concentration exceeds the calibration range of S Method of standard additions (MSA) used <br /> the instrument for calculation <br /> N Presumptive evidence of a compound (TICS only) U Compound was not detected <br /> P Concentration difference between primary and W Post digestion spike out of control limits <br /> confirmation columns>25% Duplicate analysis not within control limits <br /> U Compound was not detected + Correlation coefficient for MSA<0.995 <br /> X,Y,Z Defined in case narrative <br /> Analytical test results meet all requirements of NELAC unless otherwise noted under the individual analysis. <br /> Measurement uncertainty values, as applicable, are available upon request. <br /> Tests results relate only to the sample tested. Clients should be aware that a critical step in a chemical or microbiological <br /> analysis is the collection of the sample. Unless the sample analyzed is truly representative of the bulk of material involved, the <br /> test results will be meaningless. If you have questions regarding the proper techniques of collecting samples, please contact <br /> us. We cannot be held responsible for sample integrity, however, unless sampling has been performed by a member of our <br /> staff. This report shall not be reproduced except in full,without the written approval of the laboratory. <br /> Times are local to the area of activity. Parameters listed in the 40 CFR part 136 Table II as "analyze immediately" are not <br /> performed within 15 minutes. <br /> WARRANTY AND LIMITS OF LIABILITY-In accepting analytical work,we warrant the accuracy of test results for the sample as submitted. THE <br /> FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IS GIVEN IN LIEU OF ALL OTHER WARRANTIES,EXPRESSED OR IMPLIED. WE DISCLAIM <br /> ANY OTHER WARRANTIES,EXPRESSED OR IMPLIED,INCLUDING A WARRANTY OF FITNESS FOR PARTICULAR PURPOSE AND WARRANTY OF <br /> MERCHANTABILITY. IN NO EVENT SHALL LANCASTER LABORATORIES BE LIABLE FOR INDIRECT,SPECIAL,CONSEQUENTIAL,OR INCIDENTAL <br /> DAMAGES INCLUDING,BUT NOT LIMITED TO,DAMAGES FOR LOSS OF PROFIT OR GOODWILL REGARDLESS OF(A)THE NEGLIGENCE(EITHER <br /> SOLE OR CONCURRENT)OF LANCASTER LABORATORIES AND(B)WHETHER LANCASTER LABORATORIES HAS BEEN INFORMED OF THE <br /> POSSIBILITY OF SUCH DAMAGES. We accept no legal responsibility for the purposes for which the client uses the test results. No purchase order or other <br /> order for work shall be accepted by Lancaster Laboratories which includes any conditions that vary from the Standard Terms and Conditions,and Lancaster <br /> hereby objects to any conflicting terms contained in any acceptance or order submitted by client. <br /> 3768.07 <br /> Page 13 of 13 <br />