My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
3400
>
2300 - Underground Storage Tank Program
>
PR0518738
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/7/2021 9:58:45 AM
Creation date
5/26/2021 2:41:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0518738
PE
2361
FACILITY_ID
FA0014111
FACILITY_NAME
CHEVRON STATION #212470/2222
STREET_NUMBER
3400
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
Zip
95376
APN
21306016
CURRENT_STATUS
01
SITE_LOCATION
3400 MACARTHUR DR
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
157
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Overfill Prevention Equipment Inspection Report <br /> 6. OVERFILL PREVENTION EQUIPMENT DETAILS <br /> Tank ID (one OPE per column) 87 91 dsl <br /> Are both vent and tank riser piping f Yes a Yes r Yes r- Yes <br /> secondarily contained? r' No r No No T No <br /> OPE Model oPw oPw oPw <br /> r- Shut off 91 Shut off r Shut off r Shut off <br /> Flow Flow Flow Flow <br /> r Restricts I- Restricts I" Restricts l Restricts <br /> What is the OPE response when activated? Flow Flow Flow Flow <br /> (Check all that apply) I- Audible Audible r Audible r Audible <br /> Alarm Alarm Alarm Alarm <br /> r Visual Visual f Visual F_ Visual <br /> Alarm Alarm Alarm Alarm <br /> Are flow restrictors installed on vent piping r Yes* r' Yes* r Yes* Yes* <br /> that may interfere with the OPE operation? No No No r No <br /> At what level in the tank is the OPE set to <br /> activate? (Inches from bottom of tank) 99.625 100.625 <br /> What is the percent capacity of the tank at <br /> 91.4 90.8 <br /> which the OPE activates? <br /> Is the OPE in proper operating condition to Yes Yes r Yes r Yes <br /> respond when the stored substance reaches r No r No r No r No <br /> the designated regulatory level? <br /> 7. SUMMARY OF TESTING RESULTS <br /> r Pass r: Pass r. Pass r Pass <br /> OPE Inspection Results r: Fail r Fail r Fail Fail <br /> 8. COMMENTS <br /> Describe all results marked "Fail"and each proposed remedy. <br /> WAS NOT ABLE TO TEST REG. DO TO THE NIPPLE NOT BEING ABLE TO BE REMOVED. <br /> *Mark here if: <br /> I- Flow restrictors interfere with overfill prevention and equipment repairs required. <br /> Additional copies of this page may be attached. <br /> Attach tank chart(s), measurements, calculations, and In-Tank Setup report(s) <br />