Laserfiche WebLink
a <br /> ROOF DECK KEYNOTES GENERAL NOTES Z <br /> 10 PRE-FABRICATED COOLER WALLS, CEILING, DOORS AND RACKS. MAINTAIN 2"AIR SPACE BETWEEN 1. CONTRACTORS SHALL NOT SCALE THESE DRAWINGS. IN THE EVENT OF OMISSION OF NECESSARY 10. FIRE EXTINGUISHER: #10 CLASS ABC WITH UL RATING 4A-60BC. SURFACE MOUNTED ON WALL WITH v <br /> COOLER AND ADJACENT WALLS PER MANUFACTURES SPECIFICATIONS. CONTRACTOR TO FIELD VERIFY DIMENSIONS THE CONTRACTORS SHALL NOTIFY THE CONSTRUCTION PROJECT MANAGER. MANUFACTURERS ALL STEEL WALL BRACKET.JL INDUSTRIES INC. (COSMIC 10E)OR APPROVED EQUAL WITH w <br /> DIMENSIONS WITH PROJECT MANAGER. INSPECTION TAG AS REQUIRED BY LOCAL CODES. z <br /> I I 2. GENERAL CONTRACTOR SHALL VERIFY ALL BUILDING DIMENSIONS, AND SITE GRADES PRIOR TO START OF F_ p <br /> I [2 MOP SINK; REFERENCE PLUMBING. WORK. 11. CONTRACTOR TO INSTALL COAT HOOKS FOR EMPLOYEES. REFERENCE SHEET EF1 ITEM 220. INSTALL 2 IN (w <br /> OFFICE AND 3 IN BACKROOM. LOCATION TO BE DETERMINED BY CONSTRUCTION PROJECT MANAGER. SEE Q <br /> 4 [3 PROVIDE SPACE FOR RECESSED BOX IN WALL FOR CO2 LINES AND PVC CONDUIT FOR POST MIX AND 3. VERIFY SIZE, LOCATION,AND CHARACTERISTICS, OF ALL WORK AND EQUIPMENT TO BE FURNISHED BY OWNER DOOR HARDWARE SCHEDULES. U <br /> A2 3 SLURPEE MACHINES. OR OTHERS,WITH THE MANUFACTURER OR SUPPLIER BEFORE ANY CONSTRUCTION PERTAINING TO SAME IS W <br /> I I S'i BEGUN. 12. APPLY 3M SUN CONTROL WINDOW FILMS @ ALL SOUTH, EAST,AND WEST FACING GLASS (3M-1). NOTE NO FILM = <br /> [4 ELECTRICAL PANELS; REFERENCE ELECTRICAL SHEETS. SHOULD BE APPLIED TO THE STOREFRONT DOORS. (REFERENCE SHEET A6.1 FOR MATERIALS SCHEDULE). Y Z ZO <br /> 4. ALL EXTERIOR WALL DIMENSIONS ON THE PLANS UNLESS OTHERWISE NOTED ARE TO OUTSIDE FACE OF SIP, <br /> ]5 STEEL COLUMN; REFERENCE STRUCTURAL SHEETS. CMU BLOCK OR STRUCTURAL SHEATHING. 13. G.C. TO FURNISH AND INSTALL RIS BACKBOARD AT ISP DESK. REFERENCE MATERIALS SCHEDULE ON SHEET Q > <br /> A6.1. m Q <br /> 1- F6] DOWNSPOUT; REFERENCE ELEVATIONS SHEET A3.1. 5. 2"AIR SPACE BETWEEN COOLER WALL AND BUILDING WALL, OR ANY EQUIPMENT ADJACENT TO COOLER. <br /> WALK-IN COOLER SUPPLIED BY 7-ELEVEN, INC, INSTALLATION TO BE DETERMINED BY CONSTRUCTION 14. MOUNTING HEIGHT OF ELECTRICAL SWITCHES, RECEPTACLE OUTLETS,AND THERMOSTATS: (PER CBC 11B-308.1) w <br /> 7 5'-0"WIDE X 8'-0"TALL STAINLESS STEEL CABLE TRELLIS O/METAL FRAME, SEE 11/A7.1. PROJECT MANAGER. COORDINATE&VERIFY WITH ELECTRICAL DRAWINGS. LO Q <br /> 48" MAX.ABOVE THE FLOOR (MEASURED FROM THE TOP OF THE OUTLET BOX). N t <br /> [8 3'-6"WIDE x 2'-0" HIGH GREENHECK ESJ-401 LOUVERED VENT-PRE-FINISHED, DARK BRONZE. OPENINGS 6. CONTRACTOR TO PROVIDE AND INSTALL WALL BACKING FOR WALL HUNG FIXTURES AND TOILET 15" MIN.ABOVE THE FLOOR(MEASURED FROM THE BOTTOM OF THE OUTLET BOX). <br /> SHALL BE COVERED w/CORROSION-RESISTANT SCREEN MESH,w/OPENINGS 1/8" MIN.AND 1/4" MAX. IN ACCESSORIES. a a <br /> DIMENSIONS. SEE MECHANICAL DRAWINGS. <br /> 7. ALL WOOD IN CONTACT WITH CONCRETE MUST BE PRESSURE TREATED, MOISTURE RESISTANT WOOD. ■ ■ ■ ■ <br /> 8. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED: 5.0 L.B.F. FOR INTERIOR DOORS. WALL LEGEND This document,the ideas and <br /> 00<1 designs incorporated herein, are <br /> 9. ALL DOORS SHALL BE KEYLESS IN DIRECTION OF EGRESS. solely the property of VAI and is <br /> PREFABRICATED COOLER INTERIOR- METAL STUD WALL not to be used, in whole or in <br /> WALL <br /> I EXTERIOR-2x6 WOOD STUDS @ 16" part for any project or <br /> .00SUBSTRATE PER PLAN NOTES O.C.w/R-19 FULL BATT INSULATION duplication,without written <br /> 3 COOLER WALL © COPYRIGHT 2019 <br /> COOLER/ >00< r <br /> FREEZER <br /> U bA Nvo -'t U-) <br /> 2 <br /> t <br /> 4 13" A4.0 .. � <br /> N N <br /> 17'-6 1/2"VAULT DIM ��'-1" U7 � <br /> TOP OF CONC U `~ <br /> 2" MIN T-0 1/2"VAULT DIM 3'-4" T-2"VAULT DIM Ln Ln <br /> COOLER/ FREEZER WALLO w Ln Ln <br /> 0 O CLR. VAULT DIM 2" MIN O CCS U <br /> Z 6 CLR. ❑8 6 8 TYP. 7 6 UU U <br /> ct <br /> J - <br /> ROOF DECK ROOF DECK B - U - U - B U O w <br /> � 4 107 <br /> D FREEZER D _ G C v 000 <br /> ICE 108 E c 3 3 A ELECTRICAL A.6 M <br /> O <br /> 17 D � 107 I 4� <br /> A7.0 Q 109 <br /> S ❑ - - - - - - <br /> I I <br /> 3'-4 1/2" I I <br /> B.O. CEILING <br /> II RESTROOM <br /> A �_ 106 _� <br /> SCHEDULED CEILING I O r` <br /> I I 1 °o <br /> METAL TOP TRACK I A2.1 <br /> I I 3 <br /> 106 I 7t <br /> METAL STUD FRAMING M <br /> PER WALL TAG BELOW 3 <br /> SUBSTRATE PER PLAN \\, A4.0 / _ <br /> 0 <br /> SIM _ - ' - ' - ' - ' - ' - ' 1018 <br /> EXISTING I A 17 gnomonECTOORd,0 Q <br /> STRUCTURE/ I M C° <br /> PARTITION/ z 10'-9 1/2"VAULT DIMENSION 39'-9 1/4" 8'-8 1/2" 1D F T��\�j j ZU, <br /> STOREFRONT MTL STUD FRAMING p a, �, Q Z - <br /> J J U) 2'-8 1/2" 11'-6" 0t o U - cn <br /> J I J Z W In <br /> SUBSTRATE SOUND BATT INSULATION = 0. <br /> @ RESTROOM ONLY J �� �� W <br /> o PER PLAN O 80 <br /> W I COOLER/ 14 l w COOLER 3 �* <br /> X FREEZER A7.0 X VAULT MERCHANDISE A Q 2 - O V-O <br /> co <br /> W ��'b w 110 101 <br /> I I <br /> METAL STUD TRACK j j 2'-4" v <br /> ATTACHED W/FASTENERS _ o � <br /> @ 24"O.C. MAX. I N <br /> TOP OF CONC TOP OF CONC <br /> A3.0 2 °� c7 <br /> COOLER/FREEZER WALL 1 i ./101' ] ® N <br /> AGAINST WALL O 3-5/8" MTL. STUDS O �O E O <br /> ROOF DECKNN ROOF DECK 1'-7 3/4" . 4 A3.0 <br /> O <br /> FIN. FLOOR ELEV. = 11.0' N <br /> A <br /> 0 <br /> F.E. <br /> F.E. cD <br /> CD <br /> 17 I I 17 I V <br /> A7.0 � A7.0 � 104 0 <br /> BACKROOM z Q <br /> I I I I U <br /> I I I 104 Z <br /> 0 <br /> B.O. CEILING - I I I I LL <br /> I I I I Z J <br /> l i t _J SALES q _ Q <br /> SCHEDULED CEILING l i i SCHEDULED CEILING l i t N 102 U <br /> I I I I n Z <br /> METAL TOP TRACK \ A 0 <br /> I I I \_ > <br /> 2'-l" 35'- <br /> 4 3/4" O U <br /> METAL STUD FRAMING METAL STUD FRAMING <br /> PER WALL TAG BELOW PER WALL TAG BELOW A 111 103 OFFICE UJ w <br /> SUBSTRATE PER PLAN SUBSTRATE PER PLAN `0 4 A 103UJ <br /> } z <br /> CDC TOTE A7 o SIM. q N > Q <br /> M <br /> 111 OH °' <br /> 7 4 n <br /> O <br /> A A7.0 A7.0 _ 5 SIM. 7 LU U- <br /> MTL STUD FRAMING I i MTL STUD FRAMING i t A7.0 O.H. 5 A7.0 B <br /> Q i A.1 F E 5 BELOW A.1 J Q <br /> SOUND BATT INSULATION I I I I _ <br /> @ RESTROOM ONLY q = _ - - - - - - _ - q O UJ <br /> U 0 <br /> I I O i C B A � ' <br /> 14 i i w 14 i i L . LI J 101A LIOL �, O O <br /> A7.0 I I w A7.0 I I LL <br /> I I I I <br /> li i li it 1 2 <br /> METAL STUD TRACK i i METAL STUD TRACK i 8'-7" A4.0 A4.0 6'-11 1/4" 6'-2 1/2" <br /> ATTACHED W/FASTENERS I I ATTACHED W/FASTENERS I ISSUE DATE: 7-30-19 <br /> @ 24" O.C. MAX. I I 24"O.C. MAX. I 13'-0" 5'-4" <br /> 10'-4" 14'-8" <br /> TOP OF CONC OP OF CONC O 0000 0 C Z 18'-4" 16'-8" 25'-0" REV. DATE: <br /> 3-5/8" MTL. STUDS OB 3-5/8" MTL. STUDS O <br /> 0 0 0 0 0 0 0 0 60'-0" 0 0 0 PROJECT NO.: 18008.2 <br /> 0 <br /> 6" MTL. STUDS A•6 - 1 RB <br /> 2 WALL TYPES FLOOR PLAN A3.0 6" DIA. PIPE � of Z SHEET: <br /> 0BOLLARD @ Z <br /> 1"= U 1'-0" 1/4" = 1'-0" 2 1.2 1.1 48"O.C., SEE 2 W 1 <br /> NOTE: REFERENCE A2.2 FOR WALL 13/A7.1, TYP. 7 w> A200 <br /> FINISH AND SUBSTRATE TYPES. cl m 0 <br />