My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
770
>
1600 - Food Program
>
PR0546811
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/18/2021 9:16:42 AM
Creation date
5/26/2021 3:40:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0546811
PE
1617
FACILITY_ID
FA0026512
FACILITY_NAME
7 ELEVEN 41216H
STREET_NUMBER
770
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
CURRENT_STATUS
01
SITE_LOCATION
770 W CHARTER WAY
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a <br /> W <br /> KEYNOTES GENERAL NOTES Q <br /> 1❑ CRICKET W/TAPERED INSULATION TYP. 10 PRE-FINISHED METAL CAP FLASHING-DARK BRONZE TYP. 1. CONTRACTOR TO RESERVE SPECIFIED MAPES CANOPY UPON BEING v <br /> AWARDED THE BID TO ENSURE AVAILABILITY AND TIMELY INSTALLATION. <br /> F2 MAPES CANOPY COMES IN 5-0"SECTIONS AND 24" HANGER ROD HEIGHTS.ALL 11 NOT USED SUBSTITUTIONS ARE NOT PERMITTED. <br /> CUSTOM CANOPY DESIGNS HAVE A LEAD TIME OF 7-8 WEEKS. F_ p <br /> 12 NOT USED. W <br /> K <br /> F3 SUNOPTICS PRISMATIC SKYLIGHT, 4040 SIGNATURE SERIES,TYP. Q <br /> 13 ROOF ACCESS REF: MATERIAL SCHEDULE U � <br /> F4 R.T.U., REF MECHANICAL SHEETS. W <br /> 14 FLEX-PACK REF MECHANICAL SHEETS. = p <br /> F5 WALKING PAD TO BE A MINIMUM 30"AROUND MECHANICAL UNIT. U Z z0 <br /> 15 REFRIGERANT PIPE PORTAL. Y W <br /> F6 LOTTO SATELLITE DISH REF: ELECTRICAL SHEETS. SATELLITE DISH FOR LOTTO Q <br /> MACHINE FOR AZ, CA, CO, TX, &WA. REMOVE DISH AND CORRESPONDING 16 EXHAUST DUCT; REF PLUMBING SHEETS. m Q W <br /> 11� <br /> CABLING DETAILS IN OTHER STATES. <br /> 17 SINGLE PLY ROOFING OVER R-38 EPS FOAM INSULATION OVER PLYWOOD oN N W <br /> [7 NOT USED. SHEATHING; REF. SHEET A6.1 (MR-1). LO ~ <br /> a <br /> N N <br /> F8 NOT USED. 18 2x6 KICKERS. <br /> �9 PLUMBING VENT; REF PLUMBING SHEETS. <br /> as <br /> This document,the ideas and <br /> designs incorporated herein, are <br /> solely the property of VAI and is <br /> not to be used, in whole or in <br /> part for any project or <br /> GENERAL NOTES duplication,without written <br /> 5 6 © COPYRIGHT 2019 <br /> 1. DETAIL ELIMINATES PITCH SHEET METAL HOOD; COORD. Cj O <br /> POCKETS FOR PIPING PENETRATIONS WITH MECH SHEETS FOR REQ'D 2 .1 I� M r- r- <br /> THROUGH THE ROOF. PITCH POCKET NUMBER OF LINES SETS AND SIZE <br /> INSTALLATIONS ARE PROHIBITED. OF OPENING REQ'D. .. .4-1 '� C� <br /> N N <br /> 2. ATTACHED TREATED WOOD ,-� � V� . <br /> NAILER TO DECK WITH SUITABLE SHEET METAL OR FLEX TUBE U ct <br /> COLLAR. PROVIDE CONT. BEAD 2 U "d '� Ln Ln <br /> FASTNER AS REQ'D PER LOCAL AHJ. OF SEALANT AT COLLAR 1 3 A7.1 •r U � Ln <br /> 3. PROVIDE MIN 2" BETWEEN A7.1 <br /> PIPES AND 4" MIN CLEARANCE SHEET MTL FLASHING RECIVER A7 1 29'-4" U rz � U U ct <br /> FROM PIPE TO TOP OF CURB. <br /> WITH GASKETED FASTENERS @ _ _ <br /> Z MIN 18"O.C.AROUND PERIMETER B B y <br /> SINGLE PLY - OF PIPE PORTAL; PROVIDE Ln <br /> ROOFING PROPER FASTENING SCHEDULE a WW Lu Wa W a QCq <br /> MEMBRANE OVER O AS REQ'D PER LOCAL AHJ. O O O O O �O t1 00 <br /> LAP FLASHING AS z 1 U) � 1 � � 1 U) � Q'r <br /> REQ'D PER � = OVER FAS NERS @ 8' O C FLASHING YT ±13'-7" <br /> SLOPE SLOPE_ SLOPE SLOPE TOP OF <br /> ROOFING a ROOF SLOPE <br /> MEMBRANE = ROOFING MEMBRANE TO EXTEND SLOPE <br /> SPECIFICATIONS o MIN OF 2"ABOVE CANT o S•a <br /> 6 1 15 <br /> 1 4 1 1 <br /> -38 PS 1 ±14'-10" <br /> INSULATION A2.4 <br /> 9 16 PARAPET <br /> — — — — — — — — — <br /> ' 2 <br /> A2.4 A7.1 <br /> WOOD CANT AS REQ'D TO BRACE — ® O TYP. <br /> ROOF DECK CURB 14 14 I 5 5 13 <br /> INSULATE VOID AS REQ'D TO <br /> DETAIL @ PIPE PORTAL PREVENT CONDENSATION 3 TYP A7. _J <br /> 1 ■ ■ ■ <br /> 4 1 1/2" V-0" <br /> 1 <br /> 19'-9" V-4" QCT* b/N � Q <br /> 4'-2 1/4" gnomon .�N OORT�� Q Z <br /> OUTSIDE DIMENSION CURB _ +18'_8" 0') /> , <br /> C? PARAPET w o U <br /> Q — � <br /> 0. to <br /> SKYLIGHT; REF EF-1 �j �, <br /> SHEET SCHEDULE _ �� Q W <br /> 2X TREATED 3 `�/ * S�P�F. <br /> WOOD 2X TREATED WOOD 1 A2.4 <br /> BLOCKING VA Fd BLOCKING FOR CURB. A7 1 O I TYP. <br /> CRICKET ON 4 O - ■ ■ ■ ■ <br /> HIGH SIDE. I _ � o <br /> R-38 EPS T-11 1/4" M W <br /> FOAM ROUGH OPENING i� O !i 1 O <br /> INSULATION <br /> 14 GAUGE O A7.1 M <br /> 1/2"GYP BD INSULATED (1 1/2" <br /> "LIGHT WELL" ® N <br /> PANEL SCREW R9) CURB; PARAPET HEIGHT ABOVE <br /> P_4 PROVIDED BY ROOF MEMBRANE IS 48" <br /> WITHWASHER SUNOPTICS, O <br /> PLATE AT 12" INSTALLED BY G.C. MIN., THEREFORE UI 1 <br /> O.C.; REF SIP GUARDS ARE REQUIRED 3 � <br /> Lu <br /> SHEETS 1/2" PW w/3/16" DIA. x 1-1/4"SELF- (PER CBC 1015.6). O <br /> Lu <br /> DRILLING SHEET METAL SCREWS AT SHEET METAL SCREW 1 <br /> 6"oc AT TOP&8d NAILS AT 6"oc NEAR w/HEX-WASHER HEAD <br /> MIDDLE & BOTTOM AS SHOWN AT 6"O.C. TYP. o ■ ■ ■ ■ <br /> AROUND PERIMETER; � 17 <br /> SEE STRUCTURAL -0z 2'-7" 17'-10" <br /> CD <br /> O <br /> (D N <br /> STEEL BAR JOIST; � <br /> SEE STRUCTURAL 8'-8" T-0" 12'-9" 3'-3" O I z ■ Q <br /> : SKYLIGHT CROSS SECTION11 0 Z 0 <br /> 3 � + <br /> I I iv <br /> — Q <br /> — — CL U <br /> I I M ■� p <br /> W <br /> SKYLIGHT; REF EF-1 3 3 10 <br /> Z 0 <br /> SHEET SCHEDULE Q <br /> 1 TYP � <br /> 1 1 UJ (n <br /> UJ <br /> 2X TREATED2X TREATED WOOD M } <br /> WOOD BLOCKING; BLOCKING FOR CURB. 18 r/1 > >Q z <br /> REF SIP SHEETS TYP V� <br /> 14 GAUGE INSULATED (1 O UJ W <br /> 1/2" R9)CURB; PROVIDED TOP OF H <br /> R-38 EPS 3'-11 1/4" BY SUNOPTICS, A.1 ROOF A.1 J <br /> FOAM ROUGH OPENING INSTALLED BY G.C. Q <br /> INSULATION 1/2"GYP BUJ () LL <br /> AL <br /> ii D u A — — — — A O <br /> PANEL SCREW "LIGHT WELL" <br /> WITHWASHER P-4 1 <br /> PLATE AT 12" <br /> O.C.; REF SIP -107� A7.1 <br /> SHEETS 3' 1/4" <br /> SHEET METAL SCREW 2 <br /> WITH HEX-WASHER ISSUE DATE: 7-30-19 <br /> HEAD AT 6"O.C. TYP. 5'-2" 5'-0" 5'-0" 5'-0" 5'-0" 5'-0" 5'-2" <br /> AROUND PERIMETER; 11'-6" 35'-3" 13'-2" REV. DATE: <br /> REF SIP SHEETS <br /> PROJECT NO.: 18008.2 <br /> STEEL BAR JOIST; SEE DRAWN BY: RB <br /> STRUCTURAL <br /> SKYLIGHT SECTION ROOF PLAN z SHEET: <br /> 2 <br /> 3/4" = 11_011 1/4" = V-0" 2 1.2 1.1 1 <br /> A2 , 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.