My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOCKEFORD
>
205
>
2300 - Underground Storage Tank Program
>
PR0232257
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/23/2021 10:27:43 AM
Creation date
6/2/2021 9:29:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0232257
PE
2361
FACILITY_ID
FA0000670
FACILITY_NAME
QUIK STOP MARKET #148
STREET_NUMBER
205
Direction
W
STREET_NAME
LOCKEFORD
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04116115
CURRENT_STATUS
01
SITE_LOCATION
205 W LOCKEFORD ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Date: <br />June 21, 2021 <br /> Facility Address: <br /> 205 W LOCKEFORD ST, LODI <br /> Facility Name: <br /> QUIK STOP MARKET #148 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />CORRECTIVE ACTION: Ensure that designated operators performing visual inspections at this facility are including <br />all of the required information on the reports. <br />This is a repeat violation, Class II. <br /> 306 HSC 25291(e) Failure to remove, analyze, and properly dispose of water in secondary containment (pre-Jul 2003). <br />OBSERVATION: Liquid was observed in the following: <br />-Approximately 2 gallons of liquid was observed in the 91 fill sump. <br />-Approximately 2 gallons of liquid was observed in the 87 fill sump. <br />-Approximately 1 gallon of liquid was observed in the 89 fill sump. <br />REGULATION GUIDANCE: If water could enter into the secondary containment by precipitation or infiltration, it <br />must be removed and disposed of properly. <br />CORRECTIVE ACTION: The service technician removed all liquid from the 87, 89, and 91 fill sumps. <br />This was corrected on site. <br />This is a repeat violation, Class II. <br /> 318 CCR 2635, 2637.1, 2665, 2712 Failed to meet spill container requirements. <br />OBSERVATION: The 91 product spill container failed when tested. <br />REGULATION GUIDANCE: All USTs shall be equipped with a spill container that collects any hazardous <br />substances spilled during delivery operations, that has a minimum capacity of five gallons and a drain valve that <br />allows drainage of the collected spill into the primary container or provide a means to keep the container empty. <br />CORRECTIVE ACTION: The drain valve in spill container was adjusted and retested during the inspection. <br />This was corrected on site. <br />This is a repeat violation, Class II. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by 7/21/2021 . <br />To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br />of having them sign. Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate <br />($152). To schedule an appointment, please call (209) 468-3420. <br />FA0000670 PR0232257 SC001 06/21/2021 <br />EHD 23-01 Rev. 9/16/2020 Underground Storage Tank Program OIRPage 6 of 7 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.