COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
1137
>
2300 - Underground Storage Tank Program
>
PR0530093
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2021 10:44:37 AM
Creation date
6/2/2021 1:43:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0530093
PE
2351
FACILITY_ID
FA0019793
FACILITY_NAME
CRUISERS MANTECA #29
STREET_NUMBER
1137
Direction
W
STREET_NAME
LATHROP
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
19724002
CURRENT_STATUS
01
SITE_LOCATION
1137 W LATHROP RD
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br />Monitoring System Certification Form <br />5. MONITORING SYSTEM AND PROGRAMMING <br />A separate Monitoring System Certification Form must be prepared for each control panel <br />Make of Monitoring System <br />Model of Monitoring System <br />Software Version Installed <br />Control Panel <br />Control Panel <br />Veeder Root <br />TLS 350 <br />333.03 <br />Attach the post -certification reports if the Monitoring System is capable of <br />Yes <br />No <br />NA <br />generating either- N Monitoring System Set -Up N Alarm History Report <br />All monitoring equipment is operational per manufacturer's specifications? <br />N <br />❑ <br />Secondary containment systems are free of damage, debris, or liquid? <br />® <br />❑ <br />Are the audible and visual alarms operational? <br />® <br />❑ <br />All sensors have been: 1) visually inspected for wiring kinks, breaks and residual <br />N <br />❑ <br />❑ <br />buildup on floats; and 2) tested for functionality and confirmed operational? <br />Are all sensors installed to detect a release at the earliest opportunity in the <br />® <br />❑ <br />❑ <br />secondary containment? <br />The monitoring system setup was reviewed, and proper settings confirmed? <br />N <br />❑ <br />❑ <br />Was the monitoring control panel's backup battery visually inspected, <br />functionally tested, and confirmed operational? <br />® <br />El <br />El <br />Does the flow of fuel stop at the dispenser if a release is detected in the under- <br />❑ <br />❑ <br />N <br />dispenser containment? <br />Does the turbine automatically shut down if the piping secondary containment <br />monitoring system fails to operate or is electrically disconnected? <br />® <br />❑ <br />❑ <br />Does the turbine automatically shut down if the piping secondary containment <br />monitoring system detects a release? Which sensors initiate positive shutdown? <br />N <br />❑ <br />❑ <br />Check all that apply) N Sump N UDC <br />If monitoring system alarms are relayed to a remote monitoring center, is all <br />❑ <br />❑ <br />N <br />communication equipment operational? <br />Describe all answers marked `No" or "Fail" and proposed remedy in Section 9. <br />List all Monitoring equipment either replaced or repaired in Section 9. <br />Page 2 of 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.