Laserfiche WebLink
SA NUJ OAHU I N Environmental Health Department <br /> ■ COUNT Y-- <br /> c/ `p Greorne5S grows hey,. Timeln: 1-00pm <br /> Time Out: 1:30 om <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: RUBICON AT REYNOLDS RANCH Date: 06/02/2021 <br /> Address: 2951 REYNOLDS RANCH PKWY, LODI 95240 <br /> Owner/Operator: CALPURINA ASSOCIATES LP Telephone: <br /> Program Element: 3611 -PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #22 Skimmer Assembly <br /> OBSERVATIONS:The skimmer on the east end of the pool lacks the floating weir. Install the floating weir for this skimmer <br /> by 1 week. <br /> CALCODE DESCRIPTION:Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br /> maintained in accordance with manufacturer specifications. (CBC 31368) <br /> #35 Flow Meters <br /> OBSERVATIONS:The flow meter is stuck at 0. Free the meter in order to get a proper reading by 1 week. <br /> CALCODE DESCRIPTION:Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br /> manufacturer's specifications. (CBC 31258) <br /> #37 Electrical Hazards <br /> OBSERVATIONS:The pool lights are lacking a proper GFI shutoff type breaker. Install or confirm a GFI shutoff breaker for <br /> the pool lights by 1 week. <br /> CALCODE DESCRIPTION:Electrical equipment installed in the water, walls, deck, or equipment room of a public pool shall comply with <br /> California Electrical Code. (CEC 680.4)Light fixtures installed in the pool that operate at more than 15 volts shall be protected by a ground <br /> fault circuit interrupter. (CBC 31608) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: gpm Chlorine: 6.0 ppm Temp: ° F <br /> Cyanuric acid: <30 ppm pH: 7.6 Combined chlorine: ppm <br /> NOTES <br /> No comment entered. <br /> FA0024579 PR0542965 SCO01 06/02/2021 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />