Laserfiche WebLink
SAN J OAQU I N Environmental Health Department <br /> C)UNTY <br /> Time In: 'C00 pm <br /> Time Out: 1:50 ore <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: ARBOR MOBILE HOME PARK Date: 08/07/2018 <br /> Address: 19690 N HWY 99 , ACAMPO 95220 <br /> Owner/Operator: NEWPORT PACIFIC CAPITAL CO Telephone: (714) 852-5575 <br /> Program Element: 3611 -PUBLIC POOUSPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION-Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040, & <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #8 Pool and Deck Lighting <br /> OBSERVATIONS: Underwater pool light burn out. Repair within one week and no pool usage when is dark, post a sign <br /> according until is fix. <br /> CALCODE DESCRIPTION:Pools used at night shall be equipped with undenvaterlight fixtures that provide complete illumination of the <br /> pool. When a pool is used at night,pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br /> not operational, the pool operator shall post a sign in 4-inch letters stating"NO USE OF POOL ALLOWED AFTER DARK"and shall <br /> secure the pool area and not permit any use of the pool after dark.(3115B) <br /> #9 Ladders and Handrails <br /> OBSERVATIONS: Loose handrail. Tighten loose handrail within one week. Corrected on site. <br /> CALCODE DESCRIPTION:A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br /> handrails shall be corrosion resistant and shall be rigidly installed.At least one handrail shall extend from the deck to not less than a point <br /> above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck.(CBC 3111B)Pool <br /> operator shall keep ladders and handrails well maintained.(CCR 65535) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: 60 gpm Chlorine: 10.00 ppm Temp: ° F <br /> Cyanuric acid: >100 ppm pH: 7.2 Combined chlorine: 0.2 ppm <br /> NOTES <br /> influent 15psi <br /> effluent 11 psi <br /> The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br /> Safety Code. If a reinspection is required,fees will be assessed at the current hourly rate. <br /> Received by: Name and Title: Steve Anderson, Maintenance <br /> EH Specialist: PAUL NSO Phone: (209) 969-5628 <br /> FA0018660 PR0360004 SC001 08/07/2018 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 1 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />