My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
1617
>
2300 - Underground Storage Tank Program
>
PR0231923
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2022 9:57:45 AM
Creation date
6/7/2021 8:08:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231923
PE
2361
FACILITY_ID
FA0003606
FACILITY_NAME
ARCO 05450
STREET_NUMBER
1617
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13511015
CURRENT_STATUS
01
SITE_LOCATION
1617 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Facility Name: <br />ARCO 05450 <br />Facility Address: <br />1617 W FREMONT ST, STOCKTON, CA 95203 <br />Facility Phone: <br />(209) 462-1617 <br />Program: <br />2361 - UST FACILITY <br />Inspection Type: <br />ROUTINE INSPECTION - Operating Permit <br />Date: <br />July 06, 2021 <br />CERS ID: <br />10181235 <br />Inspection Contact: <br /> Consent For: Consent Given By: <br />Malina Korng, Clerk <br />Title:Phone: <br />() - <br />Inspection Photos Samples <br />Underground Storage Tank Program Inspection Report <br />Service Technician Manufacturer's Training: <br />VR, 03/23/22; OPW,07/06/22 <br />Service Technician Onsite: <br />Darnell Smith <br />Exp. Date: <br />11/23/2022 <br /> Designated Operator: <br />Kevin Dutra <br />Exp. Date: <br />07/29/2021 <br />HSC = Health and Safety Code CFR = Code of Federal RegulationsCCR= Title 23 California Code of Regulations <br />R = Repeat violation COS = Corrected on site during inspectionV= Violation <br />File Review <br />101 □ V □ R □ COSFailure to obtain a permit to operate from the EHD including but not limited to unpaid permit feesHSC 25284; CCR <br />2711(d) <br />102 □ V □ R □ COSFailure to submit a complete and accurate application for a permit to operate a USTCCR 2711 <br />103 □ V □ R □ COSFailure to submit the UST Certification of Installation/ModificationCCR 2635(f), 2636(c)(2) <br />104 □ V □ R □ COSFailure to have an approved UST Monitoring PlanCCR 2632(d)(1), <br />2634(d) <br />105 □ V □ R □ COSFailure to have an approved UST Response PlanCCR 2632(d)(2), <br />2634(e) <br />106 □ V □ R □ COSFailure to submit and maintain a current facility plot plan / site mapCCR 2632(d), 2641(h) <br />107 □ V □ R □ COSFailure to submit and maintain complete and current financial responsibility documentsHSC 25292.2; CCR <br />2711(a)(11) <br />108 □ V □ R □ COSFailure to implement or maintain a written agreement between the UST owner and operatorCCR 2620(b); HSC <br />25284(a)(3) <br />109 □ V □ R □ COSFailure to submit "Designated Underground Storage Tank Operator Identification Form" within 30 daysCCR 2715(a)(1)(B), <br />2715(a)(3) <br />110 □ V □ R □ COSFailure to submit the "Underground Storage Tank Statement of Understanding and Compliance Form"CCR 2715(a)(1)(A), <br />2715(a)(2) <br />111 □ V □ R □ COSFailed to notify the EHD 48 hours prior to conducting testingCCR 2637, 2638(e), <br />2643(g) <br />112 □ V □ R □ COSFailure to have properly qualified service technician test leak detection equipment every 12 monthsCCR 2638, 2641(j), <br />2715(f) <br />113 □ V □ R □ COSFailure to conduct secondary containment testingCCR 2637(a-d), 2712(b) <br />(1)(F) <br />114 □ V □ R □ COSFailure to perform line integrity test every 12 months or within 30 days of repair of primary pipeCCR 2636(f)(3), 2643(c) <br />(3) <br />115 □ V □ R □ COSFailure to submit "Monitoring System Certification Form" within 30 days of completion of the testCCR 2638(c), 2638(d) <br />116 □ V □ R □ COSFailure to submit the "Spill Container Testing Report Form" within 30 daysCCR 2637.1(d), <br />2637.1(e) <br />117 ■ V □ R □ COSFailed to submit "Secondary Containment Testing Report Form" within 30 days after the testCCR 2637(e), 2637(f) <br />118 ■ V □ R □ COSFailure to submit the "Overfill Prevention Equipment Inspection Report Form" within 30 daysCCR 2637.2(d&e), <br />2665(a&b) <br />119 □ V □ R □ COSFailure to comply with tank lining certification, testing, and inspection requirementsCCR 2663, 2712(b)(6) <br />120 □ V □ R □ COSFailure to submit and/or maintain documentation regarding compatibility for UST system componentsCCR 2631, 2640.1, <br />2665, 2711 <br />FA0003606 PR0231923 SC001 07/06/2021 <br />EHD 23-01 Rev. 9/16/2020 Underground Storage Tank Program OIRPage 1 of 5 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.