F
>
FREMONT
>
1617
>
2300 - Underground Storage Tank Program
>
PR0231923
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2022 9:57:45 AM
Creation date
6/7/2021 8:08:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231923
PE
2361
FACILITY_ID
FA0003606
FACILITY_NAME
ARCO 05450
STREET_NUMBER
1617
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13511015
CURRENT_STATUS
01
SITE_LOCATION
1617 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Date: <br />July 06, 2021 <br />Facility Address: <br />1617 W FREMONT ST, STOCKTON <br />Facility Name: <br />ARCO 05450 <br />Other Violations <br />2010 □ V □ R □ COSUnlisted General violation See below <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />117 CCR 2637(e), 2637(f) Failed to submit "Secondary Containment Testing Report Form" within 30 days after the test. <br />OBSERVATION: Secondary containment testing was performed on 5/19/2019. A test report has not been <br />submitted to the EHD or the California Environmental Reporting System (CERS). <br />REGULATION GUIDANCE: A copy of the 'Secondary Containment Testing Report Form' must be submitted within <br />30 days of the test. <br />CORRECTIVE ACTION: Immediately provide this report to the EHD. <br />This is a minor violation. <br />118 CCR 2637.2(d&e), 2665(a&b) Failure to submit the "Overfill Prevention Equipment Inspection Report Form" within <br />30 days. <br />OBSERVATION: Secondary containment testing was performed on 7/13/2020. A test report has not been <br />submitted to the EHD or the California Environmental Reporting System (CERS). <br />REGULATION GUIDANCE: A copy of the 'Secondary Containment Testing Report Form' must be submitted within <br />30 days of the test. <br />CORRECTIVE ACTION: Immediately provide this report to the EHD. <br />This is a minor violation. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by 8/5/2021 . <br />To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br />of having them sign. Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate <br />($152). To schedule an appointment, please call (209) 468-3420. <br />Documents provided during inspection: <br />Inspection report <br />Return to compliance certification <br />CUPA training class schedule <br />FA0003606 PR0231923 SC001 07/06/2021 <br />EHD 23-01 Rev. 9/16/2020 Underground Storage Tank Program OIRPage 4 of 5 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.