Laserfiche WebLink
FGL Environmental <br />Revision Date: 10/09/14 <br />Doc ID: 3DO900002_SOP_12-1.DOC <br />Page 1 of 1 <br />Inter- tory Condition Upon Receipt (Attach to COC) 21'557� <br />Sample Receipt a . STK CC CH VI <br />I. Number of ice c ests/packages received: Shipping tracking # <br />2. Were samples received in a chilled condition? Temps: .9, • q / <br />Surface water SWTR bact samples: A sample that has a temperature upon receipt of > 00° C, whether iced or not, <br />should be flagged unless the time since sample collection has been less than two hours. <br />3. Do the number of bottles received agree with the COC? No N/A <br />4. Were samples received intact? (i.e. no broken bottles, leaks etc. es No <br />5. VOAs checked for Headspace? Yes No <br />6. Were sample custody seals intact? Yes No <br />7. If required, was sample split for pH analysis? es N <br />8. Were all analyses within holding times at time of receipt? e No <br />9. Verify sample date, time and sampler name es No <br />Sign and date the COC, place in a ziplock and put int same ice ches as a samples. <br />Sample Receipt Review completed by (initials): <br />Sample Receipt at SP:97 <br />1. Were samples received in a chilled condition? Temps: / <br />Acceptable is above freezing to 6� C.12, <br />any packages are received at one time check for tests/H.T.'s/rushes/ <br />2. Shipping tracking numbers: <br />/A <br />DN -4 <br />3. D�o theLnI5 bot les receive agree with the COC? <br />g � No N/A <br />4. Were samples received intact? (i.e. no broken bottles, leaks etc.) es No <br />5. Were sample custody seals intact? Yes No 0 <br />Sign and date the COC, obtain LIMS sample numbers, select methods/tests and print labels. <br />Sample Verification, Labeling and Distribution: <br />1. Were all requested analyses understood and acceptable? <br />No <br />2. Did bottle labels correspond with the client's ID's? <br />9 <br />No <br />3. Were all bottles requiring sample preservation properly preserved? <br />No N/A FGL <br />[Exception: Oil & Grease, VOA and CM verified in labl <br />4. VOAs checked for Headspace? Yes <br />No / <br />5. Have rush or project due dates been checked and accepted? Y s <br />No / <br />6. Were all analyses within holding times at time of receipt? e <br />No <br />Attach labels to the containers and include a copy of the COC for lab delivery. <br />Sample Receipt, Login and Verification completed by (initials): <br />Discrepancy Documentation: <br />Any items above which are "No" or do not meet specifications (i.e. temps) must be resolved. <br />1. Person Contacted: Phone Number: <br />Initiated By: Date: <br />Problem: <br />Resolution: <br />2. Person Contacted: <br />Initiated By: San Joaquin County EHD <br />San <br />Problem: STU135727 <br />Resolution: <br />srp 04/27/2021 16:17:56 <br />se the back of this sheet for additio: <br />contacts)here <br />IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII <br />