Laserfiche WebLink
May 5, 2021 Lab ID : STK2135171 <br /> San Joaquin Co.Environmental Health Dep Customer : 3-17919 <br /> Quality Control - Inorganic <br /> Constituent Method Date/ID Type Units Cone. QC Data DQO Note <br /> Wet Chem <br /> Nitrate 300.0 (VI 2142834-001) MSD mg/L 40.00 88.3% 85-119 <br /> MSRPD m 10.00 1.3% <19 <br /> 300.0 04/16/21:205853MCA ICB mg/L 0.000 0.5 <br /> ICV mg/L 20.00 103% 90-110 <br /> CCB mg/L 0.000 0.5 <br /> CCV m 20.00 103% 90-110 <br /> Nitrate+Nitrite as N 300.0 04/16/21:204132MCA Blank mg/L ND <0.I <br /> Nitrate Nitrogen 300.0 04/16/21:204132MCA Blank m ND <0.1 <br /> Nitrite 300.0 04/16/21:204132MCA Blank mg/L ND <0.5 <br /> LCS mg/L 15.00 102% 90-110 <br /> MS mg/L 30.00 102% 74-126 <br /> (STK2135171-001) MSD mg/L 30.00 103% 74-126 <br /> MSRPD mg/L 10.00 1.2% <20 <br /> MS mg/L 30.00 100% 74-126 <br /> (VI 2142834-001) MSD mg/L 30.00 104% 74-126 <br /> MSRPD m 10.00 3.2% <20 <br /> 300.0 04/16/21:205853MCA ICB mg/L 0.000 0.5 <br /> ICV mg/L 15.00 102% 90-110 <br /> CCB mg[L 0.000 0.5 <br /> CCV mg/L 15.00 103% 90-110 <br /> Nitrite Nitrogen 300.0 04/16/21:204132MCA Blank mg/L ND <0.2 <br /> Sulfate 300.0 04/16/21:204132MCA Blank mg/L ND <0.5 <br /> LCS mg/L 50.00 107% 90-110 <br /> MS mg/L 100.0 106% 82-124 <br /> (STK2135171-001) MSD mg/L 100.0 107% 82-124 <br /> MSRPD mg/L 10.00 1.4% <23 <br /> MS mg/L 100.0 100% 82-124 <br /> (VI 2142834-001) MSD mg/L 100.0 104% 82-124 <br /> MSRPD mg/L 10.00 2.6% <23 <br /> 300.0 04/16/21:205853MCA ICB mg/L 0.000 0.5 <br /> ICV mg/L 50.00 107% 90-110 <br /> CCB mg/L 0.208 0.5 <br /> CCV mg/L 50.00 107% 90-110 <br /> MBAs 5540C 04/16/21:206003jba CCB mg/L -0.0393 0.25 <br /> CCV mg/L 1.000 97.8% 90-110 <br /> CCB mg/L -0.0393 0.25 <br /> CCV mg/L 1.000 97.8% 1 90-110 <br /> MBAs Extraction 5540C 04/16/21:204476jba Blank mg/L ND <0.1 <br /> LCS mg/L 0.5000 97.4% 86-114 <br /> BS mg/L 0.5000 93.4% 86-114 <br /> BSD mg/L 0.5000 96.3% 86-114 <br /> BSRPD m 0.5000 0.015 <0.1 <br /> Definition <br /> ICV :Initial Calibration Verification-Analyzed to verify the instrument calibration is within criteria. <br /> ICB :Initial Calibration Blank-Analyzed to verify the instrument baseline is within criteria. <br /> CCV :Continuing Calibration Verification-Analyzed to verify the instrument calibration is within criteria. <br /> CCB :Continuing Calibration Blank-Analyzed to verify the instrument baseline is within criteria. <br /> Blank :Method Blank-Prepared to verify that the preparation process is not contributing contamination to the samples. <br /> LCS :Laboratory Control Standard/Sample-Prepared to verify that the preparation process is not affecting analyte recovery. <br /> MS Matrix Spikes-A random sample is spiked with a known amount of analyte.The recoveries are an indication of how that sample <br /> matrix affects analyte recovery. <br /> MSD :Matrix Spike Duplicate of MS/MSD pair-A random sample duplicate is spiked with a known amount of analyte.The recoveries <br /> are an indication of how that sample matrix affects analyte recovery. <br /> BS :Blank Spikes-A blank is spiked with a known amount of analyte.It is prepared to verify that the preparation process is not <br /> affecting analyte recovery. <br /> Page 8 of 9 <br />