My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0083077
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRETHEWAY
>
16018
>
4200/4300 - Liquid Waste/Water Well Permits
>
SR0083077
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/7/2021 4:14:13 PM
Creation date
6/7/2021 3:09:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200/4300 - Liquid Waste/Water Well Permits
RECORD_ID
SR0083077
PE
4222
FACILITY_NAME
16018 N TRETHEWAY RD
STREET_NUMBER
16018
Direction
N
STREET_NAME
TRETHEWAY
STREET_TYPE
RD
City
LODI
Zip
95240
APN
05120065
ENTERED_DATE
12/28/2020 12:00:00 AM
SITE_LOCATION
16018 N TRETHEWAY RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN 10AQUIN <br />COUNTY <br />Greatness grows here. <br />Environmental Health Department <br />PERCOLATION TEST/SOIL PROFILE INSPECTION CHECKLIST <br />SJC Ordinance Code, Title 9, Section 9-1105.2 <br />EHD Policy for Percolation Test Procedure 98-01 <br />Site Location: 16 <br />v y e Date: <br />I Q s 'Z© Z <br />Test Performed b '2 Permit#: <br />D 3a� PAM <br />SITE MAP <br />Includes pert test and soil profile locations with accurate measurements from a fixed reference point (must be able to locate <br />the test hole areas in the future). Perc/soil profile holes must meet distance setbacks as noted in the sewage standards for <br />septic system locations. Percolation test holes and soil profile pits must be conducted in the area proposed for future septic <br />systems. <br />Notes any changes in elevation on the subject property. <br />Notes all water wells. <br />Notes all man-made features septics stems, drives, barns, outbuildings, animal pens, etc. <br />Notes all natural features ephemeral drainage courses, large stands of trees, ponds, rivers, etc. <br />PERC TEST PREPARATION PROTOCOL <br />ate and time of test hole preparation. 'L 2D?i0 <br />NZ <br />Diameter and depth of test hol (4"- " diameter and 36"-42" depth). 3 `� <br />Dimensions and depth of deep test hole 4"-12" diameter and 42"-25' or minimum 10' abbe seasonal high water table). <br />Test hole preparation(scoring of sidewalls, removal of loose material). <br />Weather conditions at time of testing (raining, windy, etc. <br />Soil type and condition encountered in test hole. <br />ddition of 2" of course sand or fine gravel to test hole. <br />Pre-soak by addition of minimum 12" of water over gravel (24 -hours before test). <br />P RC TEST CONDITIONS, MEASUREMENTS, AND REPORTING <br />ondition of test hole after the 24-hour re -soak amount of water remaining in the hole, any soil sloughing noted). <br />Correct amount of water used to refill hole 6" over gravel). Documented on the recordation sleet. <br />Description of type of perc test procedure used based on conditions Procedure #1, #2,((r#30 <br />Accurate recordings of drop and refill of water in same measurements. <br />Same fixed reference point used for each reading. Description of reference point used to be included in the final report. <br />Math calculations checked for accuracy. <br />Beginning and end measurements of the last reading verified by REHS. All above reviewed and verified by REHS. <br />SOIL PROFILE <br />Description of the date, time, and protocol used to prepare soil profile pit. <br />Description of soil profile pit including depth and dimensions. <br />Soil lithology described by appropriate professional using industry standard pr tocol. <br />COMMENTS L V,0 ;? ( 03 ✓n �Ie%n CA <br />REHS Name: <br />Y, <br />Calculations Examples: <br />Last drop reading = .07' over 30 minutes time. <br />.07' x 12" = .84" (convert from feet to inches) <br />30 minutes _ .84" = 35.7 minutes/inch <br />Last drop reading =1.2' over 10 minutes time. <br />1.2' x 12" = 14.4" (convert from feet to inches) <br />10 minutes - 14.4" =,69 minutes/inch <br />EHD4200-xx 5-1-2018 <br />1868 E. Hazelton Avenue � Stockton, California 95205 1 T 209 468-3420 1 F 209464-0138 1 uvvvw.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.