Laserfiche WebLink
Environmental Health Department <br />Time In: <br />11:30 am <br />10:45 am <br />Time Out: <br />Program Element: 3616 - PUBLIC POOL/SPA - EXEMPT <br />Telephone: (209) 838-3591 Owner/Operator: ESCALON UNIFIED SCHOOL DISTRIC <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 1528 E YOSEMITE AVE, ESCALON 95320 <br />Date: 06/07/2021Name of Facility: ESCALON USD-ESCALON HIGH SCH <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #9 Ladders and Handrails <br />OBSERVATIONS: Two of three hand rails and both ladders are loose. Fix in 1 week. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: All twelve pool skimmers are lacking weir gates. Provide weir gates in 1 week. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br /> #38 Filter Cleaning and Maintenance <br />OBSERVATIONS: Difference between the Influent and Effluent measurements are exceeding the 10 PSI. Back wash the <br />filter in 1 week. <br />CALCODE DESCRIPTION: All filters shall be maintained in accordance with manufacturer's specifications. (CBC 3123B) Pressure gauge <br />located on the filter shall be marked with the clean startup reading. (CBC 3125B) Each filter vessel shall be provided with valves so that it <br />can be isolated from the recirculation system for repairs and backwashing. (CBC 3128B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F 676 <br />7.4 <br />7 <br /><30 Combined chlorine:ppm0.2 <br />NOTES <br />pool inspection. <br />Pool is 10 Ft depth, diving is allowed and life guards on site. <br />Pool lights are not used and when they use the pool, closing hour is 5PM. <br />Life ring and body hook are on site. <br />Influent 12 PSI <br />Effluent 1 PSI <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0000325 PR0360041 SC001 06/07/2021 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD