My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOLLY
>
20500
>
2300 - Underground Storage Tank Program
>
PR0502021
>
REMOVAL_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/14/2021 11:41:38 AM
Creation date
6/9/2021 3:39:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
2021
RECORD_ID
PR0502021
PE
2361
FACILITY_ID
FA0005302
FACILITY_NAME
SPRECKELS SUGAR COMPANY
STREET_NUMBER
20500
STREET_NAME
HOLLY
STREET_TYPE
DR
City
TRACY
Zip
95304
APN
21216010
CURRENT_STATUS
02
SITE_LOCATION
20500 HOLLY DR
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
164
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ 0 A Q U1 N Environmental Health Department <br />-COUNTY--- <br />SAMPLING PROTOCOL FOR ROUTINE TANK REMOVALS <br />The following represents minimum sampling criterion required for closure compliance. Soil samples collected shall be <br />representative of native soils beneath the tank's invert (tank's bottom) at a collection depth not to exceed 2 - 4 feet. If <br />contamination is documented during closure, an Unauthorized Release Notification must be completed and submitted within <br />five (5) working days pursuant to California Health & Safety Code, Section 25295. Samples cannot be combined into a <br />composite sample for analysis in the field or the lab. Each sample must have a set of corresponding analytical <br />results. <br />WATER NOT PRESENT IN THE TANK PIT <br />PIPING AND STOCKPILE <br />TANK SIZE <br />MINIMUM NUMBER of <br />LOCATION of SOIL <br />TANK <br /># <br />TANK SIZE <br />(Gallons) <br />MINIMUM NUMBER <br />of SOIL SAMPLES <br />LOCATION OF SOIL SAMPLES <br />SAMPLES <br />TANK & PIPING STOCKPILE SAMPLES <br />2 Samples every 50 cubic yards <br />< 11000 <br />1 per Tank <br />Fill OR Pump End of Tank <br />< 11000 <br />1,000 - 101000 <br />2 per Tank <br />1 at each End of Tank <br />X <br />> 10,000 <br />3 or More <br />per Tank <br />Ends and Middle OR generally <br />spaced along the length of the Tank <br />1 <br />Single Tank <br />5 OR More per Tank <br />PIPING AND STOCKPILE <br />WATER IS PRESENT IN TANK PIT <br />TANK <br />TANK SIZE <br />MINIMUM NUMBER of <br />LOCATION of SOIL <br />MINIMUM NUMBER of <br />PIPING SOIL SAMPLES <br />1 Sample every 20 lineal feet <br />SOIL SAMPLES <br />SAMPLES <br />TANK & PIPING STOCKPILE SAMPLES <br />2 Samples every 50 cubic yards <br />WATER IS PRESENT IN TANK PIT <br />TANK <br />TANK SIZE <br />MINIMUM NUMBER of <br />LOCATION of SOIL <br />MINIMUM NUMBER of <br /># <br />(Gallons) <br />SOIL SAMPLES <br />SAMPLES <br />WATER SAMPLES <br />< 11000 <br />3 per Tank <br />2 from wall next to tank <br />< 10,000 <br />3 <br />ends at soil/groundwater <br />1 <br />Single Tank <br />5 OR More per Tank <br />interface & 1 below tank <br />4 from wall next to tank <br />> 10,000 OR <br />ends at soil/groundwater <br />1 <br />X <br />Tank Cluster <br />5 or more <br />interface & 1 below each <br />tank <br />SLAB PRESENT IN THE TANK PIT <br />Soil samples shall be obtained beneath the slab within native soils. Penetration through the obstruction will be required in <br />order to collect the samples. (Physical removal of the obstruction will allow sampling according to the above conditions.) <br />Tri -Regional Recommendations —Appendix A <br />TANK <br /># <br />TANK SIZE <br />(Gallons) <br />MINIMUM NUMBER <br />of SOIL SAMPLES <br />LOCATION of SOIL SAMPLES <br />< 11000 <br />3 per Tank <br />Center and Ends OR Sides of Tank <br />1,000 - 10,000 <br />5 per Tank <br />Center and Ends OR Sides of Tank <br />> 101000 <br />5 OR More per Tank <br />Ends and Middle and generally spaced <br />along the length of the Tank <br />Tri -Regional Recommendations —Appendix A <br />
The URL can be used to link to this page
Your browser does not support the video tag.