Laserfiche WebLink
SAN JOAQUIN <br />1-1,J NTY— <br />Environmental Health Department <br />Time In: 10 An am <br />Time Out: 11:40 am <br />Swimming Pool Official Inspection Report <br />Name of Facility: COLONY NORTH APARTMENTS <br />Date: 07/23/2019 <br />Address: 258 LANCASTER DR, MANTECA 95336 <br />Owner/Operator: EAVENSON, RALPH, BILL & BEV <br />Telephone: (209) 823-2572 <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected vfithin specified timehame. Violations that are classified as "MAJOR' pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br />#8 Pool and Deck Lighting <br />OBSERVATIONS: The pool light is pushed in a little bit, exposing some of the encasing behind the light The light and GFI <br />work properly. The light casing is not loose (pushed it with pole). Repair pool light fixture. <br />CALCODE DESCRIPTION.Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br />pool. When a pool is used at night, pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br />not operational, the pool operator shall post a sign in 4 -inch letters stating "NO USE OF POOL ALLOWED AFTER DARK" and shall <br />secure the pool area and not permit any use of the pool after dark. (31158) <br />#13 Cyanuric Acid Concentration <br />OBSERVATIONS: The cyanuric acid is greater than 100 ppm. Lower below 100 ppm before next season. <br />CALCODE DESCRIPTION: Pool operator shall maintain cyanuric acid concentration between 0.0 ppm and 100 ppm. (CCR 65530) <br />#38 Filter Cleaning and Maintenance <br />OBSERVATIONS: The filter needs to be backwashed. Maintenance person said that it is backwashed once a week. <br />Backwash filter when influent and effluent pressure difference is greater than 10 psi. <br />CALCODE DESCRIPTION: All filters shall be maintained in accordance with manufacturer's specifications. (CBC 31238) Pressure gauge <br />located on the filter shall be marked with the clean startup reading. (CBC 31258) Each filter vessel shall be provided with valves so that it <br />can be isolated from the recirculation system for repairs and backwashing. (CBC 31288) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate: 55 gpm Chlorine: 2.6 ppm <br />Cyanuric acid: >100 ppm <br />NOTES <br />influent 26 psi <br />effluent 7 psi <br />Temp: 0 F <br />Combined chlorine: 0.4 ppm <br />FA0001097 PRO360331 SC001 07/23/2019 <br />EHO 36-01 Rev. 06=i15 Page 1 of 2 Swimming Paol OR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />