Laserfiche WebLink
SAN J O A Q U I N Environmental Health Department <br />—COUNTY— <br />, Time In: g 19,m <br />Greatness <br />Time Out: 10:15 am <br />Swimming Pool Official Inspection Report <br />Name of Facility: COLONY NORTH APARTMENTS <br />Date: 07/20/2020 <br />Address: 258 LANCASTER DR, MANTECA 95336 <br />Owner/Operator: EAVENSON, RALPH, BILL & BEV <br />Telephone: (209) 823-2572 <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR"pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br />#3 Safety Signs <br />OBSERVATIONS: Pool capacity and address signs are not available. Post signs in 1 week. <br />CALCODE DESCRIPTION Pool operator shall keep safetysigns well maintained. (CCR 55535) Safety signs shall have clearly legible <br />letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall, pole, gate, or similar <br />permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 31208) <br />_#7 Pool Deck. <br />OBSERVATIONS: Pool deck has 3 patches and cracks at the double hand rail and one patch at 3 Ft depth. Seal in 2 <br />weeks. <br />CALCODE DESCRIPTION: An unobstructed 4 -foot wide deck of concrete or like materia/ shall be provided and maintained flush with the <br />top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br />diving board, ADA device, or slide. (CBC 31148) Pool operator shall keep the pool deck well maintained. (CCR 65535) <br />#22 Skimmer Assembly <br />OBSERVATIONS: Skimmer is lacking weir gate. Provide weir gate in 1 week. <br />CALCODE DESCRIPTION.. Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 31368) <br />OBSERVATIONS: Flow meter is stuck. Repair/ replace in 1 week. <br />CALCODE DESCRIPTION.. Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 312513) <br />#38 Filter Cleaning and Maintenance <br />OBSERVATIONS: Difference between the influent and effluent is greater than 10 PSI. Back wash the filter in 2 days. <br />CALCODE DESCRIPTION: All filters shall be maintained in accordance with manufacturer's specifications. (CBC 31238) Pressure gauge <br />located on the fitter shall be marked with the clean startup reading. (CBC 31258) Each filter vessel shall be provided with valves so that it <br />can be isolated from the recirculation system for repairs and backwashing. (CBC 31285) <br />PRO360331 SC001 07/20x2020 <br />EHD 3601 Rev. 06130115 Page 1 of 2 Swimming Pool OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />