Laserfiche WebLink
Time In: 11,05 am <br />7 ime Out: 11:45 am <br />qe N San Joaquin County <br />'a�cOc <br />_ 1 Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, CA 95205-6232 <br />., `p.. Telephone: (209) 468-3420 Fax: (209) 464-0138 Web: www.sigov.org/ehd <br />4clpa'n+ <br />Swimming Pool Official Inspection Report <br />Name of Facility: PINES MOBILEHOME PARK, THE <br />Date: 08/05/2015 <br />Address: 6706 TAM O SHANTER DR, STOCKTON 95210 <br />Owner/Operator: DOWNEY, BRAD <br />Telephone: <br />Program Element: 3611 - PUBLIC POOL/SPA- PRIMARY <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br />#1 Pool Gates <br />OBSERVATIONS: Self latching on gate sticky. Repair so it self -latches every time in 1 day. <br />VIOLATION DESCRIPTION., Gates and doors leading into the pool area shall be equipped with self-dosingself-latching devices. <br />Self -latching devices shall be designed to keep the gate or door securely closed. Gates and doors shall open outward from the pool area <br />except where otherwise prohibited bylaw. (CBC 31198) Pool operator shall keep gates and doors leading into the pool area well <br />maintained. (CCR 65535) <br />#8 Pool and Deck Lighting <br />OBSERVATIONS: Pool light being repaired, not attached into wall at this time. Repair and reattach in 1 day. <br />VIOLATION DESCRIPTION: Pools used at night shall be equipped with underwaterlight fixtures that provide complete illumination of the <br />pool. When a pool is used at night, pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br />not operational, the pool operator shall post a sign in 4 -inch letters stating "NO USE OF POOL ALLOWED AFTER DARK" and shall <br />secure the pool area and not permit any use of the pool after dads. (3115B) <br />#22 Skimmer Assembly <br />OBSERVATIONS: Float assembly lacking in skimmers. Provide in 3 days. <br />VIOLATION DESCRIPTION., Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br />#35 Flow Meters <br />OBSERVATIONS: Flow meter stuck. Provide. <br />VIOLATION DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br />#36 Pressure and Vacuum Gauges <br />OBSERVATIONS: No effluent gauge. Provide in 3 days. <br />VIOLATION DESCRIPTION: Pressure and vacuum gauges shall be provided for each pump system. (CBC 3125B) <br />FA0002503 PR0360106 SCO01 08/05/2015 <br />EHD 36-01 Rev. 06/30/15 Page 1 of 2 Swimming Pool OR <br />