My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
1011
>
2900 - Site Mitigation Program
>
PR0542507
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2021 11:10:26 AM
Creation date
6/11/2021 10:55:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0542507
PE
2950
FACILITY_ID
FA0024435
FACILITY_NAME
J & D AUTO
STREET_NUMBER
1011
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04740007
CURRENT_STATUS
01
SITE_LOCATION
1011 S CHEROKEE LN
P_LOCATION
02
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br />AdvancedGeo <br />Environmental <br />05 January 2018 <br />AGE Project No. 18-4265 <br />Page 4 of 6 <br />vapor sample collection. Once the tubing and vapor-tip are in place, a filter pack of #3 <br />sand will be placed from the bottom of the borehole to one-foot above the vapor tip. <br />Following placement of the filter pack, dry bentonite crumbles will be placed atop the filter <br />pack. Thereafter, bentonite chips will be placed and hydrated to near surface grade to <br />seal the vapor well from ambient air intrusion. <br />Following soil-vapor well installations, a minimum of one hour stabilization period will be <br />observed prior to sample collection at each of the vapor point well locations. A one-liter <br />Summa canister and a 6-liter purge canister will be connected together with a dedicated <br />and serialized sampling inlet manifold. The sampling inlet manifold will consist of an <br />air/vapor-tight valve; a particulate filter; a calibrated flow restrictor calibrated to 200 <br />milliliters per minute (ml/min), a stainless steel tee-fitting, two vacuum gauges at either <br />end of the controller and connections for both purge and sampling canisters (manifold <br />assembly). The manifold assembly will be attached to the 1/4-inch Teflon® tubing from the <br />vapor sampling locations. The purge canister will be attached to the end of the sampling <br />manifold while the sample canisters will be attached to the tee-fitting between the tubing <br />and purge container. <br />Leak tests will be performed on each soil-vapor sampling assembly by attaching and <br />securing the sample and purge canisters to the manifold and opening the valve on the <br />purge canister and the manifold. The leak test will be performed for approximately 3 to 5 <br />minutes on each assembly. <br />Upon achieving a successful leak test, the purge canister valve will be opened for a <br />calculated period of time to allow for three volumes of air to be purged. The purge canister <br />vacuum gauge will be monitored to ensure a proper decrease of vacuum ensuring flow <br />and purging. The purge volume will be determined by calculating the internal volume of <br />the tubing and open borehole area. <br />Upon achieving the targeted purge volume, the purge canister valve will be closed and <br />the sample canister valve will be opened. The initial pressure and time will be recorded. <br />Upon reaching at least -5 in Hg or less, the sample canister valve will be closed and final <br />pressure and time recorded. The sampling port on the sampling canister will be capped <br />with a brass end-cap. <br />All soil-vapor samples will be labeled with sample ID, project name, date, time, and <br />samplers' initials. The samples will be logged on a chain-of-custody form, and placed into <br />dry containers. Subsequently, all collected soil-vapor samples will be delivered to a <br />California Department of Public Health (CDPH)-certified analytical laboratory, for <br />analysis.
The URL can be used to link to this page
Your browser does not support the video tag.