My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
930
>
2900 - Site Mitigation Program
>
PR0542541
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2021 11:19:59 AM
Creation date
6/11/2021 10:57:40 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0542541
PE
2950
FACILITY_ID
FA0024463
FACILITY_NAME
ALL MINI VANS AND MINI TRUCKS AUTO DISMANTLER
STREET_NUMBER
930
Direction
E
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16718303
CURRENT_STATUS
01
SITE_LOCATION
930 E CHARTER WAY
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Based on the preliminary site information including evaluation of the hazards at the site and Partner's experience, <br />personal protective equipment (PPE) will be required for all personnel and visitors entering the controlled portion <br />of the site. PPE for each potential level of protection is described below. Both Level C and D PPE should be <br />available on-site during all phases of the project, as conditions may change and require additional PPE. Work <br />should be conducted in Level D and no breathing protection will be required as long as monitored breathing zone <br />vapor concentrations remain in the nominal operation action level. <br />If on-site personnel find that breathing zone concentrations remain above nominal operation action level for more <br />than 5 minutes, then the SSO or PM will make a determination if breathing protection is needed. At this time, all <br />work in the affected area should be suspended until a decision is made. Implementation of Level C PPE will be <br />required if work continues during elevated breathing zone concentrations. Donning and use of respirators shall be <br />performed in accordance with manufacturer specifications. Replacement of respirator cartridges shall be performed <br />in accordance with manufacturer specifications. All respirators and cartridges shall be stored in air tight bags while <br />not in use. <br />Please refer to the PPE Levels of Protection for a detailed description of the equipment associated for each level of <br />PPE. <br />PPE Levels of Protection <br />Level D (to be used at all times) is as follows: <br />Full-length pants and shirt; <br />Sturdy steel-toe work boots; <br />Hard hat; <br />Safety glasses. <br />Modified Level D (used as appropriate) is as follows: <br />Regular Tyvek coveralls; <br />Outer gloves: leather, cotton, or nitrile; <br />Inner gloves: latex or nitrile; <br />Sturdy steel-toe work boots; <br />Hard hat; <br />Safety glasses. <br />Level B (used as appropriate) is as follows: <br />Positive-pressure, full-face piece, self-contained <br />breathing apparatus (SCBA) or positive-pressure <br />supplied air respirator with escape SCBA <br />(NIOSH-approved); <br />Disposable chemical-resistant coveralls <br />(Polycoated Tyvek); <br />Outer gloves: neoprene or nitrile; <br />Inner gloves: latex or nitrile; <br />Sturdy steel-toe work boots; <br />Petroleum-resistant covers over work boots; <br />Hard hat. <br />Level C (used as appropriate) is as follows: <br />Half-face air purifying, canister equipped <br />respirator (NIOSH-approved) equipped with <br />Organic Vapor/HEPA cartridges/filters; <br />Regular Tyvek coveralls; <br />Outer gloves: leather, cotton, or nitrile; <br />Inner gloves: latex or nitrile; <br />Sturdy steel-toe work boots; <br />Hard hat; <br />Decontamination Procedures <br />Drilling and sampling equipment will arrive decontaminated and clean. All downhole soil and groundwater <br />sampling equipment (e.g., sampling tubes, split spoons, hand augers, Hydropunch, etc.), tools, purge pumps, water <br />level indicators, etc. will be decontaminated before, between, and after use with Alconox or an equivalent <br />phosphate-free detergent solution to reduce the risk of cross-contamination. Decontamination of all sampling <br />Partner Site-Specific Health and Safety Plan Page 4 <br />Version 1.02 February 1,2018
The URL can be used to link to this page
Your browser does not support the video tag.