Laserfiche WebLink
S A N J D AR I N Environmental Health Department <br /> U U ,t+ I Y <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> S B GAS&MARKET 515 W ELEVENTH ST, TRACY July 28, 2021 <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 102 CCR 2711 Failure to submit a complete and accurate application for a permit to operate a UST. <br /> OBSERVATION: The UST Facility Operating Permit Application contains an incorrect California Department of Tax <br /> and Fee Administration (CDTFA) Underground Storage Tank Account Number.The number in CERS 44043961 <br /> has closed as of 9/30/2020. <br /> REGULATION GUIDANCE: The application for a permit to operate an underground storage tank shall include the <br /> CDTFA registration number issued to the owner of the tank, in accordance with HSC 25286. <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS), update the <br /> required information, and submit for review by the EHD. <br /> This is a minor violation. <br /> 107 HSC 25292.2; CCR 2711(a)(11)Failure to submit and maintain complete and current financial responsibility <br /> documents. <br /> OBSERVATION: Financial responsibility documents have not been submitted to the EHD. The most recent <br /> financial responsibility documents in CERS are dated: <br /> -7/8/2020 for Certificate of Financial Responsibility <br /> -7/9/2020 for Letter from Chief Financial Officer <br /> REGULATION GUIDANCE: Current financial responsibility documents are required to be submitted annually. <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS)at <br /> http://cers.calepa.ca.gov/, and upload the required documents. <br /> This is a repeat violation, Class II. <br /> 122 CCR 2712(f)Failure to implement corrections and submit written response within 30 days of receiving the report. <br /> OBSERVATION:An inspection was last done on 7/9/2020 and an inspection report was issued identifying <br /> information to be submitted to bring this site into compliance. This information was required to be submitted by <br /> 8/8/2020. This information has not been received resulting in a non-compliant status for this facility. <br /> REGULATION GUIDANCE:An operator that receives an inspection report shall have 30 days to implement the <br /> corrections specified in the inspection report and comply with permit conditions. The corrective action shall include <br /> all of the recommendations made in the report. The operator shall submit a written response that includes a <br /> statement documenting corrective actions taken or proposing corrective actions which will be taken. <br /> CORRECTIVE ACTION: Ensure that a written response documenting corrective actions taken or proposed is <br /> submitted and all corrections implemented within 30 days of receiving an inspection report. <br /> This is a repeat violation, Class II. <br /> FA0003539 PR0231400 SCO01 07/28/2021 <br /> EHD 23-01 Rev.9/16/2020 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />