My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
310
>
2900 - Site Mitigation Program
>
PR0544214
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/14/2021 2:31:20 PM
Creation date
6/14/2021 11:33:59 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0544214
PE
2960
FACILITY_ID
FA0025131
FACILITY_NAME
FORMERLY 424 VAN BUREN ST
STREET_NUMBER
310
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
137410020
CURRENT_STATUS
01
SITE_LOCATION
310 W FREMONT ST
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
171
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DATA GAP ASSESSMENT WORK PLAN AND PATH TO CLOSURE REVIEW <br />Chase Chevrolet, 424 N. Van Buren Street <br />Proposed Scope of Work <br />January 2, 2018 <br /> <br />4.8 SOIL VAPOR SAMPLE COLLECTION AND ANALYSIS <br />Soil vapor samples will be collected from the soil vapor probe following a minimum vapor <br />equilibration time period of 48 hours. Prior to the collection of soil vapor samples from probes SV- <br />1, SV-2, and SV-3, Stantec will verify that a significant precipitation event has not occurred within <br />5 days prior to the scheduled sampling event. <br />The soil vapor samples will be collected using 1-liter(L) or less Summallm canisters, which will be <br />obtained from a California DHS-certified laboratory with the proper vacuum of approximately 30 <br />inches of mercury (in Hg). Teflon® tubing will be used to connect the probes to SummaTM <br />canisters fitted with flow regulators restricting flow to less than 200 millimeters per minute <br />(mL/min) and in-line particulate filters. Additionally, a Swagelok® type valve will be installed on <br />the down-hole side of the flow regulator/particulate filter assembly to allow for the performance <br />of a 10-minute leak check. Prior to sample collection, soil vapor well purging will be performed <br />using a 6-L SummaTm canister installed in-line with the sample canister using a sampling tee. <br />Schematics of the soil vapor sampling apparatus are included as Figure 3. <br />Field procedures for the collection of vapor samples are outlined in Appendix E. A vacuum of <br />approximately 5 in Hg or less will be left in the sample canisters at the completion of sampling. <br />Sample collection and helium tracer gas monitoring data for each sampling location will be <br />recorded on the soil vapor sample collection data log provided in Appendix F. <br />Soil vapor samples will be sent to a California DHS-certified laboratory under chain-of-custody <br />documentation and analyzed for the presence of TPHg, BTEX, MTBE, and naphthalene using US- <br />EPA Method TO-15 Modified in full scan mode, and for the presence of atmospheric gases <br />oxygen (02), carbon dioxide (CO2), methane (CH4), and helium using American Standard <br />Testing Materials (ASTM) Method D-1946 Modified. Since helium is routinely used by laboratories <br />as a carrier gas, helium as a target compound will be specifically requested on the chain-of- <br />custody. <br /> <br />4.9 SENSITIVE RECEPTOR SURVEY <br />Stantec proposes to perform a sensitive receptor survey 1,000 feet from the boundaries of the <br />site. The following tasks will be performed during the sensitive receptor survey. <br />4.9.1 Agency Survey <br />Stantec will submit a Well Drillers Report Inspection Request and Agreement form signed by the <br />CVRWQCB to the Department of Water Resources (DWR) to access well completion records. <br />Once approved, Stantec will review well completion records at the DWR office and identify <br />water wells within 1,000 feet from the boundaries of the plume. Stantec will also contact the <br />MUD to identify the potential presence of wells within the proposed search area. <br />Stantec <br />bm \ \us1312- <br />f02 \ workgroup \ 1857 \ active \ 185703766 \ 05_report_deliv \ deliverable \work_plan\185703766_20180102_424_van_buren_work_plan_final.docx 4.4