My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0083652_SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BEZLEY
>
22370
>
2600 - Land Use Program
>
SR0083652_SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/10/2022 9:34:40 AM
Creation date
6/14/2021 2:31:19 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SR0083652
PE
2602
STREET_NUMBER
22370
Direction
N
STREET_NAME
BEZLEY
STREET_TYPE
RD
City
CLEMENTS
Zip
95227
APN
01926054
ENTERED_DATE
5/4/2021 12:00:00 AM
SITE_LOCATION
22370 N BEZLEY RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
112
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S = Sufficient <br />I = Insufficient <br />S I 6.0 PERCOLATION TEST INFORMATION SECTION <br />6.1 Site map showing the location, with concise and accurate dimensions of the percolation test holes on the parcel. <br />1K1 ▪ 6.2 The minimum number of shallow and deep percolation tests was performed for each parcel. <br />6.3 Description of the date, time and protocol used to prepare the test hole, including depth and dimensions of hole, <br />preparation of hole, and depth of water used to presoak (minimum 12 inches). <br />[Z1 ▪ 6.4 Description of the date, time and condition of the test hole after the 24-hour soak period (hole still intact, hole dry, <br />depth to water remaining in hole, etc.) <br />EE1 1=1 6.5 The test conformed to SJC Policy EHD 02-02 (correct depth, diameter, 2" gravel, 6" water refill, correct readings <br />recorded). <br />6.6 Complete Percolation Test Form (including readings) was provided with REHS verification signature. The rate <br />was correctly calculated using the last reading. <br />0 n 6.7 Discussion of any potential problems predicted and/or the need for an engineered or alternative septic system. <br />6.8 Discussion of percolation rates in relation to the type, size and location of future leach fields needed at the site. <br />7.0 CONCLUSION SECTION <br />/El ▪ 7.1 The report was signed and stamped by the appropriately registered individual <br /> <br />Reviewed By: <br /> <br />Reviewed Date: 61//z 4'11 <br /> <br />El-ID 26-02-003 <br /> Page 2 of 3 <br />Soil Suitability Checklist <br />infAnn