Laserfiche WebLink
,-0t9YIN 6 <br />L44 144 <br />a <br />Greatness grows here. <br />SANJOAQUIN <br />COUNTY <br />Environmental Health Department <br />Linda Turkatte, REHS, Director <br />Kasey Foley, REHS, Assistant Director <br />PROGRAM COORDINATORS <br />Robert McClellan, REHS <br />Jeff Carruesco, REHS, RDI <br />Michael Kith, REHS <br />Willy Ng, REHS <br />Muniappa Naidu, REHS <br />04/24/2019 <br />South Lathrop LLC <br />Attn: David Lazares <br />16795 Lark Ave, Suite 106 <br />Los Gatos, CA 95032 <br />RE: Out of Service Well Inspection <br />Well Location: 18635 S. McKinley Ave Lathrop 95337 Permit #: WP0039478 Inspection Date: 04/19/2019 <br />The Environmental Health Department recently conducted a "out of service" water well inspection at the above <br />address and found the following issues at the time of the inspection. In order to protect the ground water <br />supply and your water source from potential degradation, please take the associated corrective actions. <br />El Lack of or Inadequate Concrete Platform around Wellhead. <br />(SJC Water Well Standards, Section 4.10. — Surface Seal) <br />Corrective Action: Repair existing or install a new concrete platform around the wellhead. <br />M Lack of or Inadequate Sanitary Seal at Wellhead. <br />(SJC Ord. Code, Title 9, Section 9-1115.5. —Well Regulations) <br />Corrective Action: Install a sanitary seal between casing and well cover plate/seal all gaps and <br />openings. <br />El The well is not marked, it is difficult to identify. <br />(SJC Water well Standards, Section 5.1.3.0ut of Service Wells) <br />Corrective Action: Mark the location of the well with a pole/post so that it can easily be identified, <br />and to prevent damage. <br />El Lack of or Inadequate Backflow Prevention. <br />(SJC Water Well Standards, Section 4.14.— Backflow Prevention) <br />Corrective Action: Install an approved protective device to prevent backflow and/or back <br />siphonage into a well. <br />El Sounding Tube or Air Vent not Sealed. <br />(SJC Water Well Standards, Section 4.13.— Sounding Tube/Air Vent Pipe) <br />Corrective Action: Sounding Tube or Fill Pipe-Install a watertight, threaded cap at the upper end <br />of the pipe. Air Vent-extend pipe 12 inches above with end inverted in a <br />downward direction and covered with 16-mesh screening. <br />El Excessive Vegetation or debris around Wellhead. <br />(SJC Ord. Code, Section 9-1115.4. — Dangerous/Nuisance) <br />Corrective Action: Remove and maintain debris and vegetation away from well area. <br />If you have any questions, contact: Aaron Gooderham, Environmental Health Assistant (209) 468-3442, <br />Michael Kith, REHS <br />Program Coordinator <br />1868 E. Hazelton Avenue I Stockton, California 95205 I T 209 468-3420 F 209 464-0138 I www.sjcehd.com