Laserfiche WebLink
Environmental Health Department <br /> vii fir : ' <br /> COUNTY <br /> OUT Time In: 1010 am <br /> Time Out: 11:15 am <br /> r'�JFOSx'tYY r Garottes grows here. <br /> Swimming Pool Service Request Inspection Report <br /> Name of Facility: Date: 03/31/2021 <br /> Address: 717 W ATHERTON DR, MANTECA 95336 <br /> Requestor: JOHN RUNYAN, TROPICAL POOLS Telephone: (209)605-2444 <br /> Program Element: 3601 -NEW POOL/SPA PLAN CHECK Request#: SR0081877 <br /> Inspection Type: 523-Plan Check/Report Review <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043,116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> NOTES <br /> Pre plaster inspection for the pool and spa <br /> Each pump on a pool system shall be connected to at least two suction outlets.The suction outlets shall be hydraulically <br /> balanced and symmetrically plumbed through one or more"T"fittings and shall be separated by a distance of at least 3 feet <br /> (915 mm)in any dimension between the suction outlets. 31376.1 <br /> Fencing shall be a minimum of 5 feet high. Openings, holes or gaps in the enclosure, doors and/or gates shall not allow the <br /> passage of a 4-inch diameter sphere.The enclosure shall be constructed over a hard and permanent material equivalent to <br /> concrete: and shall be designed and constructed so that it cannot be readily climbed by small children. Horizontal and diagonal <br /> member designs which might serve as a ladder for small children are prohibited. Horizontal members'shall be spaced at least <br /> 48 inches apart..No planter or other structures that can be climbed shall be permitted within 5 feet of the outside of the pool <br /> enclosure or within a 5 foot arc. 31196.1 <br /> The overhang for either bull-nosed coping or cantilevered decking shall not exceed 2 inches(51 mm)or be less than 1 inch <br /> (25 mm)and shall not exceed 2'/2 inches(64 mm)in thickness. 31126.3 <br /> Complete the above prior to plaster. <br /> Call for an inspection. <br /> The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br /> Safety Code.If a reinspection is required,fees will be assessed at the current hourly rate. <br /> Received by: Name and Title: <br /> EH Specialist: VIDAL PEDRAZA Phone: <br /> SR0081877 SC523 03/31/2021 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 1 Swimming Pool Service Request Inspection Report <br />