My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
RIPON
>
1641
>
3600 - Recreational Health Program
>
PR0544736
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 3:59:13 PM
Creation date
6/15/2021 3:56:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0544736
PE
3612
FACILITY_ID
FA0023665
FACILITY_NAME
SFC LUXE INVESTORS LLC
STREET_NUMBER
1641
Direction
N
STREET_NAME
RIPON
STREET_TYPE
RD
City
RIPON
Zip
95366
CURRENT_STATUS
01
SITE_LOCATION
1641 N RIPON RD
P_LOCATION
05
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANAOAQUIN <br /> <br />Enviro antal Health Department <br />COUNTY <br />Gates and doors shall be equipped with self-closing and self-latching devices to <br />keep them securely closed. Gates and doors shall open outwardly away from the <br />pool except where otherwise prohibited by law. Hand activated door or gate <br />opening hardware shall be located at a height no lower than 42 inches but no <br />higher than 44 inches above the deck or walkway. The pool enclosure shall have <br />a least one means of egress without a key for emergency purposes. Gates shall <br />meet 3119B.2 of California Building Code, Title 24. <br />One guarded jet drinking fountain shall be provided for the first 250 pool users <br />and an additional fountain shall be provided for each additional 200 pool users <br />unless water is available at adjacent living quarters, or in an adjacent building <br />such as clubhouse or recreational facility. <br />10.A flowmeter must be installed on a horizontal straight run of pipe with a minimum <br />of 10 pipe diameters before and 4 pipe diameters after the flowmeter. It should <br />be positioned after the filter and before the heater. I may be installed after the <br />heater, if a great enough distance can be maintained so that heated water will not <br />damage the flowmeter. <br />11. Depth markers required at maximum depth, minimum depth, each end, break in <br />slope, on perimeter at increments not exceeding 25 feet. Pool width greater than <br />20 feet: Slip-resistant depth markers required on edge of deck. Depth markers <br />shall have numerals a minimum of 4 inches in height and of color contrasting with <br />the background, and be marked in units of feet and inches. Abbreviations of FT <br />and IN may be used in lieu of feet and inches; and be slip resistant when they are <br />located on the pool deck. <br />12 The sump for backwashing the filtration system must be sized to meet the flow. <br />Provide calculations for the sump to this department. <br />Provide the EHD with a photometric plan of the deck area. An adequate amount <br />of deck lighting shall be provided, which is at least three-foot candles. <br />All suction outlets must be hydraulically balanced and symmetrically plumbed <br />through one or more "T" fittings, and separated by a distance of at least three feet <br />in any direction between the suction outlets. <br />. Pipes shall be sized so flow velocity of piping systems including all parts and <br />fittings other than inlet devices or venturi throats shall not exceed 6 feet per <br />second in any suction and 8 feet per second in any portion of the return system. <br />16.31126.3 Where perimeter overflow systems are not provided, a bull-nosed <br />coping or cantilevered decking of reinforced concrete, or material equivalent in <br />strength and durability, with rounded slip resistant edges shall be provided. The <br />overhang for either bull-nosed coping or cantilevered decking shall not exceed 2 <br />2 of 3
The URL can be used to link to this page
Your browser does not support the video tag.