Laserfiche WebLink
SAN J O A Q U I N Environmental Health Department <br />Food Program Service Request Inspection Report <br />Facility Name and Address: SWEET SATISFACTION, 5308 PACIFIC AVE, STOCKTON 95201 <br />#36 Equipment/Utensils/Linens: Proper Storage / Use <br />OBSERVATIONS: Provide a wall bracket at mop basin for brooms, mops, ect. Correct by 1 week. <br />CALCODE DESCRIPTION: All clean and soiled linen shall be properly stored non-food items shall be stored and displayed separate from <br />food and food -contact surfaces. (114185.3 - 114185.4) Utensils and equipment shall be handled and stored so as to be protected from <br />contamination. (114074- 114075, 114081, 114119 114121, 114161, 114178, 114179, 114083, 114185, 114185.2, 114185.5) <br />#38 Approved/ Sufficient Ventilation and Lighting <br />OBSERVATIONS: Several lights are burned out. Replace by 1 week. <br />CALCODE DESCRIPTION: Exhaust hoods shall be provided to remove toxic gases, heat, grease, vapors and smoke and be approved by <br />the local building department. Canopy -type hoods shall extend 6" beyond all cooking equipment. All areas shall have sufficient ventilation <br />to facilitate proper food storage. Toilet rooms shall be vented to the outside air by a screened openable window, an air shaft, or a <br />light -switch activated exhaust fan, consistent with local building codes. (114149, 114149.1) Adequate lighting shall be provided in all areas <br />to facilitate cleaning and inspection. Light fixtures in areas where open food is stored, served, prepared, and where utensils are washed <br />shall be of shatterproof construction orprotected with light shields. (I 14149.Z 114149.3, 114252, 114252.1) <br />#39 Thermometers Provided/Accurate/Easily Visible <br />OBSERVATIONS: By 1 week provide thermometers for the small 1 door coolers at customer service area. <br />CALCODE DESCRIPTION: An accurate easily readable metal probe thermometer suitable formeasuring temperature of food shall be <br />available to the food handler. Athermometer +/- 2 #F shall be provided for each hot and cold holding unit of potentially hazardous foods <br />and high temperature warewashing machines. (114157, 114159) <br />#41 Plumbing Maintained; Approved Back Flow Device <br />OBSERVATIONS: Waste lines for ice machine drop into floor sink. Raise as to provide a one inch air gap between end of <br />drain line and rim of floor sink. Correct by 1 week. <br />CALCODE DESCRIPTION: The potable water supply shall be protected with a backflow or back siphonage protection device, as required <br />by applicable plumbing codes. (114192) All plumbing and plumbing fixtures shall be installed in compliance with local plumbing <br />ordinances, shall be maintained so as to prevent any contamination, and shall be kept clean, fully operative, and in good repair. Any hose <br />used for conveying potable water shall be of approved materials, labeled, propedy stored, and used for no other purpose. (114171, <br />114189.1, 114190, 114193, 114193.1, 114199, 114201, 114269) <br />#45 Floors, Walls, Ceilings; Clean and Maintained <br />OBSERVATIONS: Missing ceiling panel at dry storage shall be replaced by 1 week. <br />CALCODE DESCRIPTION: The walls /ceilings shall have durable, smooth, nonabsorbent, light-colored, and washable surfaces. All floor <br />surfaces, other than the customer service areas, shall be approved, smooth, durable and made of nonabsorbent material that is easily <br />cleanable. Approved base coving shall be provided in all areas, except customer service areas and where food is stored in original <br />unopened containers. Food facilities shall be fully enclosed. All food facilities shall be kept clean and in good repair. (114143 (d), <br />114266, 114268, 114268.1, 114271, 114272) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />FA0007148 SR0083792 SCO61 06/02/2021 <br />EHD 16-23 Rev. 09/16/2020 Page 2 of 3 Food Program Service Request Inspection Report <br />