My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2575
>
2300 - Underground Storage Tank Program
>
PR0231070
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2023 11:45:32 AM
Creation date
6/23/2021 8:34:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231070
PE
2351
FACILITY_ID
FA0006439
FACILITY_NAME
COUNTRY CLUB MOBIL CIRCLE K
STREET_NUMBER
2575
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
2575 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax; (209)468-3433 Web:www.sjaov.orcI/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> COUNTRY CLUB MOBIL CIRCLE K 2575 COUNTRY CLUB BLVD STOCKTON January 29 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 304 HSC 25290.1(d) Monitoring system not maintained to detect entry into secondary containment(after Jul 2004). <br /> The S3 sensor was found in 'no vac' alarm at the time of arrival and could not be tested. The continuous monitoring <br /> system shall be maintained to detect the entry of the liquid or vapor phase of the hazardous substance stored in the <br /> primary containment into the secondary containment and to detect water intrusion into the secondary containment. <br /> Correct immediately by having a properly licensed, trained, and certified contractor replace the failed component with a <br /> functional component(LG 113-x listed, if applicable) and obtain a permit within one business day from the EHD. If the <br /> failed component can't be replaced immediately, there is a possibility that the [GRADE] UST system may be red <br /> tagged to prevent fuel inputs. <br /> This is a minor violation. <br /> 305 HSC 25290.1(e)VPH monitoring of the interstitial spaces of the UST system is not maintained. <br /> The communication of the interstitial space inside the Under Dispenser Containment(UDC) 3/4 failed when tested, <br /> indicating that no continuous communication exists between the entire interstitial space. The underground tank <br /> system shall be designed and constructed with a continuous monitoring system capable of detecting the entry of the <br /> liquid or vapor-phase of the hazardous substance stored in the primary containment into the secondary containment <br /> and capable of detecting water intrusion into the secondary containment. Correct immediately by having a properly <br /> licensed, trained, and certified contractor replace the failed component with a functional component(LG 113-x listed, if <br /> applicable) and obtain a permit within one business day from the EHD. If the failed component can't be replaced <br /> immediately, there is a possibility that the UST system may be red tagged to prevent fuel inputs <br /> This is a repeat violation, Class II. <br /> 308 CCR 2636(f) Failed to maintain a continuous monitoring system that activates an audible and visual alarm. <br /> The 91 annular sensor failed to activate an audible and visual alarm when tested to ensure continuous monitoring of <br /> the tank system. All monitoring equipment shall be maintained to activate an audible and visual alarm or stop the flow <br /> of product at the dispenser when it detects a leak. The sensor was troubleshot by the technician and retested during <br /> the inspection. <br /> This is a minor violation. <br /> 319 CCR 2635, 2637.1, 2665, 2712 No spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be <br /> tested. <br /> The 87 spill container failed when tested. All spill containers shall have a minimum capacity of five gallons and be <br /> capable of containing a spill or overfill until it is detected or cleaned up. Immediately contact a properly licensed, <br /> trained, and certified contractor to repair or replace the spill container under permit and inspection of the EHD. <br /> This is a minor violation. <br /> FA0006439 PR0231070 SCO01 01/29/2019 <br /> EHD 23-01 Rev.09/22/16 Page 6 of 7 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.