Laserfiche WebLink
SAN-JOAQUIN Environmental Health Department <br /> COUNTY <br /> —"` •- Time In: 825 am <br /> Greotness grows here. <br /> Time Out: 9:10 am <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: MOTEL 6#1330 Date: 06/14/2021 <br /> Address: 817 NAVY DR, STOCKTON 95206 <br /> Owner/Operator: D TRAC HOTEL LLC Telephone: (775)250-1810 <br /> Program Element: 3611 -PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #2 Pool Enclosure <br /> OBSERVATIONS:Three metal bars are bent. Straiten them up by end of week. <br /> CALCODE DESCRIPTION:Pool area shall be enclosed by one or more of the following:a fence,portion of a building, wall, or other <br /> approved durable enclosure.Pool enclosure shall be constructed over a hard permanent material equivalent to concrete and shall be <br /> installed no more than 2 inches above the finished grade. Holes,gaps,or openings in the enclosure shall not allow the passage of a <br /> 4-inch diameter sphere.Doors, openable windows,or gates of living quarters shall not be permitted as part of the pool enclosure. (CBC <br /> 31198) Pool operator shall keep the pool enclosure well maintained. (CCR 65535) Pool enclosure shall have a minimum effective <br /> perpendicular height of 5 feet and shall be constructed so that it cannot be climbed by small children.Horizontal members shall be spaced <br /> at least 48 inches apart. No planters or other climbable structures shall be permitted within 5 feet of the pool enclosure or within a 5-foot <br /> arc. Chain link openings shall not be larger than 1314 inches when measured horizontally. Pool enclosures with a height of 4 or more feet <br /> are allowed if the enclosure was constructed prior to July 1994. (CBC 31198) <br /> #3 Safety Signs <br /> OBSERVATIONS:Write on safety signs pool capacity and hours.Also write facility name and address; phone number of <br /> nearest hospital. Correct before pool reopens to customers(it is currently closed by owner). <br /> CALCODE DESCRIPTION:Pool operator shall keep safety signs well maintained. (CCR 65535)Safety signs shall have clearly legible <br /> letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall,pole,gate, or similar <br /> permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 31206) <br /> #17 Cleanliness of Pool <br /> OBSERVATIONS:Pool has dirt. Sweep bottom of pool on a routine basis. <br /> CALCODE DESCRIPTION:Pool operator shall maintain clean pool water while the pool is in use and shall not allow debris to accumulate <br /> in the pool. Pool operator shall clean the bottom, sides,and other surfaces of the pool as often as necessary to keep pool surfaces clean <br /> and free of slime and algae. (CCR 65533) <br /> #29 Recirculation System Operation <br /> OBSERVATIONS:Filter pressure is high. Clean and maintain at under 10. <br /> CALCODE DESCRIPTION:Recirculation system shall be in operation whenever the pool is available for use and additional times as <br /> needed to maintain clear pool water. (CCR 65525) <br /> FA0002787 PR0360002 SCO01 06/14/2021 <br /> EHD 36-01 Rev.09/16/2020 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />