Laserfiche WebLink
`'.. ll � � �A�] I N Environmental Health Department <br /> `- Irl +lJ <br /> L.. v•:v COUNTY <br /> 7fa�p[rr85S grows here. Time In: 830 am <br /> Time Out: 9:00 am <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: VINTAGE SQUARE APTS Date: 06/02/2021 <br /> Address: 1176 ROSEMARIE LN, STOCKTON 95207 <br /> Owner/Operator: VINTAGE PROPERTY LP Telephone: (209)478-0310 <br /> Program Element: 3612-PUBLIC POOL/SPA-ADDITIONAL <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit Reinspection on or after: 06/03/2021 <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #2 Pool Enclosure <br /> OBSERVATIONS:West/south metal bars are bent.They shall be straighten immediately(repeat violation) <br /> Fence bar#19 to the left of the gate is loose. It shall be repaired immediately to prevent unauthorized access into pool area. <br /> CALCODE DESCRIPTION:Pool area shall be enclosed by one or more of the following:a fence,portion of a building, wall, or other <br /> approved durable enclosure.Pool enclosure shall be constructed over a hard permanent material equivalent to concrete and shall be <br /> installed no more than 2 inches above the finished grade. Holes,gaps,or openings in the enclosure shall not allow the passage of a <br /> 4-inch diameter sphere.Doors, openable windows,or gates of living quarters shall not be permitted as part of the pool enclosure. (CBC <br /> 31198) Pool operator shall keep the pool enclosure well maintained. (CCR 65535) Pool enclosure shall have a minimum effective <br /> perpendicular height of 5 feet and shall be constructed so that it cannot be climbed by small children.Horizontal members shall be spaced <br /> at least 48 inches apart. No planters or other climbable structures shall be permitted within 5 feet of the pool enclosure or within a 5-foot <br /> arc. Chain link openings shall not be larger than 1314 inches when measured horizontally. Pool enclosures with a height of 4 or more feet <br /> are allowed if the enclosure was constructed prior to July 1994. (CBC 31198) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: 35 gpm Chlorine: 8.6 ppm Temp: ° F <br /> Cyanuric acid: 45 ppm pH: 7.8 Combined chlorine: 0.2 ppm <br /> NOTES <br /> Influent 10 <br /> Effluent 0 <br /> North Pool <br /> The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br /> Safety Code.If a reinspection is required,fees will be assessed at the current hourly rate. <br /> Received by: Name and Title: Robert Bennet, pool service <br /> EH Specialist: MARIBEL FLOHRSCHUTZ Phone: (209)616-3051 <br /> FA0001219 PR0360237 SCO01 06/02/2021 <br /> EHD 36-01 Rev.09/16/2020 Page 1 of 1 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />