My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EIGHT MILE
>
800
>
3600 - Recreational Health Program
>
PR0541303
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/24/2021 9:25:42 AM
Creation date
6/24/2021 9:14:59 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0541303
PE
3611
FACILITY_ID
FA0010044
FACILITY_NAME
ELKHORN RESERVE
STREET_NUMBER
800
Direction
W
STREET_NAME
EIGHT MILE
STREET_TYPE
RD
City
STOCKTON
Zip
95209
APN
08403001
CURRENT_STATUS
01
SITE_LOCATION
800 W EIGHT MILE RD
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8. All deck areas must have a slope of no less than 1 percent (1/8-inch per foot) but <br /> no more than 2 percent (1/4-inch per foot) away from the pool. <br /> 9. All return lines and skimmer lines must be hydraulically balanced. <br /> 10.One guarded jet drinking fountain shall be provided for the first 250 pool users <br /> and an additional fountain shall be provided for each additional 200 pool users <br /> unless water is available at adjacent living quarters, or in an adjacent building <br /> such as clubhouse or recreational facility. <br /> 11.Gates and doors shall be equipped with self-closing and self-latching devices to keep <br /> them securely closed. Gates and doors shall open outwardly away from the pool except <br /> where otherwise prohibited by law. Hand activated door or gate opening hardware shall <br /> be located at a height no lower than 42 inches but no higher than 44 inches above the <br /> deck or walkway. The pool enclosure shall have a least one means of egress without a <br /> key for emergency purposes. <br /> 12.The showers must be provided with hot and cold water. A means to limit hot water to <br /> 110°F maximum shall be provided to prevent scalding. <br /> 13. Public toilet facilities must be located within 300 feet in travel distance, and available <br /> when the pool is in use. If required at the pool area, must meet Title 24 Section 31166 <br /> of California Code of Regulations. <br /> 14. The handrails on the stairs must 28 inches to 36 inches from any step and from the <br /> deck to the top of the rail. <br /> 15. The pool without stairs or ramp at the shallow end can only be used as a special <br /> purpose pool. It can only be used for instruction. <br /> Any item(s) inadvertently overlooked on the plan check may be cause for reconstruction <br /> at the pool. Please contact Adrienne Ellsaesser at (209) 468-0343 or Vidal Pedraza at <br /> (209) 468-0334 to schedule the required inspections. <br /> Since�rell�y,, <br /> nc <br /> Adrienne Ellsaesser;R.E.H.S. <br /> Program Coordinator <br /> Plan Check <br /> 02/05/2016 -2- <br />
The URL can be used to link to this page
Your browser does not support the video tag.