My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EIGHT MILE
>
800
>
3600 - Recreational Health Program
>
PR0541303
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/24/2021 9:25:42 AM
Creation date
6/24/2021 9:14:59 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0541303
PE
3611
FACILITY_ID
FA0010044
FACILITY_NAME
ELKHORN RESERVE
STREET_NUMBER
800
Direction
W
STREET_NAME
EIGHT MILE
STREET_TYPE
RD
City
STOCKTON
Zip
95209
APN
08403001
CURRENT_STATUS
01
SITE_LOCATION
800 W EIGHT MILE RD
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CERTIFICATE OF INSTALLATION-USER INSTRUCTIONS CF2R-PLB-03-E <br /> Pool And Spa Heating Systems (Page 1 of 2) <br /> MR-PLB-03-E User Instructions <br /> A.POOL AN D SPA SYSTEM TYPE <br /> Pick from Pool only,Spa only,or Pool and Spa <br /> B.SYSTEMS AND EQUIPMENT(SECTION 114.0(A)) <br /> Before any pool or spa heating system or equipment may be installed,the manufacturer must certify to the Energy Commission that <br /> the system or equipment complies with§110.4 and§110.5.The requirements include minimum heating efficiency according to <br /> Appliance Efficiency Regulations,an on-off switch outside the heater,permanent and weatherproof operating instructions, no <br /> continuous pilot light,and no electric resistance heating <br /> C.INSTALLATION(SECTION 114.0(8)) <br /> A time switch or similar control mechanism must be installed as part of the pool water circulation control system thatwill allow all <br /> pumps to be set or programmed to run only during the off-peak electric demand period and for the minimum time necessary to <br /> maintain the water in the condition required by applicable public health standards <br /> D.PUMP SIZING AND FLOW RATE SPECIFICATION(SECTION 150.0(P)) <br /> The pool filtration flow rate may not be greater than the rate needed to turn over the pool water volume in 6 hours or 36 gpm, <br /> whichever is greater.Calculate Max Flow Rate using the following equation: <br /> Max Flow Rate(gpm)=Pool Volume(gallons) <br /> 360min. <br /> Pool piping must be sized according to the maximum flow rate needed for all auxiliary loads.Show work to calculate return and <br /> suction line flow rate,minimum filter area,and the maximum pump flow rate correspond to the pool volume in accordance to <br /> section 1S0.0(p),or refer to Table C below for the prescriptive values.The maximum velocity allowed is 8 fps in the return line and 6 <br /> fps in the suction line,and the maximum pump flow rate is less than 6 hour filtration turnover. <br /> 03 Select whether the alternative calculation is used. <br /> 06 Enter the Pool volume <br /> 07 Enter the Return Pipe Diameter(inches). <br /> 09 Enter Suction Pipe Diameter(inches). <br /> 10 Enter Filter Type(Cartridge,Sand,DE). <br /> 11 Enter Filter Surface Area(ft ). <br /> 12 Enter the Max Pump Flow Rate(gpm). <br /> 13 Enter the measure flow rate of the return line in feet per second.This is only used if the alternative calculation is used. <br /> 14 Enter the measure flow rate of the return line in feet per second.This is only used if the alternative calculation is used. <br /> 15 Verify that an alternative compliance calculation or flow test result is provided for this pool or spa use(D.03=Yes),and verify <br /> whether D. 13 is less than or equal to D.08,and D. 14 is less than or equal to D.06. Indicate Yes or No. If no, project fails prescriptive <br /> compliance. <br /> E.SYSTEM PIPING <br /> There must be a length of straight pipe that is greater than or equal to at least 4 inches pipe diameters installed before the pump. <br /> Refer to Table D below for the required pipe length.Traditional hard 90°elbows are not allowed.All elbows must be sweep elbows <br /> or a type of elbow that has a pressure drop less than the pressure drop of straight pipe with a length of 30 pipe diameters. <br /> F.FILTRATION EQUIPMENT <br /> Backwash valves must be sized to the diameter of the return pipe or two inches,whichever is greater. Multiport backwash valves <br /> have a high pressure drop and are discouraged. <br /> CA Building Energy Efficiency Standards-2013 Residential Compliance March 2015 <br />