Laserfiche WebLink
Environmental Health Department <br />Time In: <br /> 1:15 pm <br />12:40 pm <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: Owner/Operator: PINNACLE CALIFORNIA CORP <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 1451 W CENTER ST, MANTECA 95336 <br />Date: 06/23/2021Name of Facility: STONEGATE APARTMENTS <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #7 Pool Deck <br />OBSERVATIONS: I observe cracks on the pool deck by the left side single handrail. Seal cracks in 1 week. <br />CALCODE DESCRIPTION: An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br />top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br />diving board, ADA device, or slide. (CBC 3114B) Pool operator shall keep the pool deck well maintained. (CCR 65535) <br /> #8 Pool and Deck Lighting <br />OBSERVATIONS: Pool light fixtures are off and I could not test the GFCI. Repair / replace the light fixtures in 2 weeks and <br />meanwhile post sign " NO SWIMMING AFTER DARK' till adequate light provided. <br />CALCODE DESCRIPTION: Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br />pool. When a pool is used at night, pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br />not operational, the pool operator shall post a sign in 4-inch letters stating "NO USE OF POOL ALLOWED AFTER DARK" and shall <br />secure the pool area and not permit any use of the pool after dark. (3115B) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: Pool skimmers are lacking float valves. Provide float valves in 1 week. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F 120 <br />7.4 <br />2.2 <br />50 Combined chlorine:ppm <br />NOTES <br />Pool inspection. <br />Influent 20 PSI <br />Effluent 15 PSI <br />Kit and maintained log are on site. <br />Life ring and body hook are on site. <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0000937 PR0360642 SC001 06/23/2021 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD