Laserfiche WebLink
Environmental Health Department <br />Time In: <br />11:50 am <br />10:30 am <br />Time Out: <br />Program Element: 3612 - PUBLIC POOL/SPA - ADDITIONAL <br />Telephone: (209) 507-7850 Owner/Operator: REDBRIDGE OWNERS ASSOCIATION <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 2965 REDBRIDGE RD, TRACY 95377 <br />Date: 06/30/2021Name of Facility: REDBRIDGE OWNERS ASSOCIATION <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #12 pH Level MAJOR <br />OBSERVATIONS: The pH level of the spa is 8.0. Adjust the pH level to 7.2 to 7.8 immediately or face closure. <br />Corrected on site: Re-check of pH level is 7.4 <br />CALCODE DESCRIPTION: Pool operator shall maintain pH between 7.2 and 7.8. (CCR 65530) <br /> #11 Combined Chlorine Concentration <br />OBSERVATIONS: The combined chlorine level of the spa is 4.8ppm. Reduce the combined chlorine level to the range of <br />0.0 to 0.4 ppm. <br />CALCODE DESCRIPTION: Pool operator shall maintain combined chlorine concentration below 0.4 ppm. (CCR 65530) Chemical quality <br />of pool water and indoor air quality at the pool site shall not cause adverse physiological effects, such as irritation of the eyes, lungs, or <br />skin. (CCR 65531) <br /> #18 Pool Shell and Tile <br />OBSERVATIONS: Some of the plaster in the spa is pitted. Re-plaster the spa by next routine inspection. <br />CALCODE DESCRIPTION: Pool shells shall be white and have a smooth waterproof interior finish that will withstand repeated brushing, <br />and scrubbing. A spa pool may be finished in a light color other than white when approved by the enforcement agency. (CBC 3108B) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: One of the float valve assemblies at the skimmers has a missing flap (it has broken off). Repair/replace <br />float valve assembly by 2 weeks. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br /> #35 Flow Meters <br />OBSERVATIONS: The flow meter for the spa is "stuck." Repair/replace the flow meter to proper function by 2 weeks. <br />CALCODE DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0018720 PR0527627 SC001 06/30/2021 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD