My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MORADA
>
4027
>
1600 - Food Program
>
PR0546917
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/18/2021 9:40:14 AM
Creation date
7/1/2021 4:32:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0546917
PE
1623
FACILITY_ID
FA0026589
FACILITY_NAME
FROSTED LUV
STREET_NUMBER
4027
Direction
E
STREET_NAME
MORADA
STREET_TYPE
LN
City
STOCKTON
Zip
95212
CURRENT_STATUS
01
SITE_LOCATION
4027 E MORADA LN STE #120
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
U <br /> J Z <br /> z GENERAL REFLECTED CEILING NOTES: LnO <br /> J <br /> W <br /> 0 LIGHT FIXTURE HAGER WIRE ® 1. PERMANENT ARTIFICIAL LIGHT SOURCES ARE TO BE MAINTAINED TO PROVIDE AT LEAST 30 <br /> Z EA. CORNER OF FIXTURE, TYP. FOOTCANDLES OF LIGHT ON ALL FOOD PREPARATION SURFACES AND AT EQUIPMENT OR UTENSIL _ Z Z <br /> 0 12 GA. SPLAY BRACING WIRE <br /> WASHING WORK LEVELS. X v <br /> J ® CORNERS OF LIGHT FIXTURE (858) 733-2445 <br /> 2. PERMANENT ARTIFICIAL LIGHT SOURCES ARE TO BE MAINTAINED TO PROVIDE AT LEAST 20 <br /> z 12 GA. VERTICAL HANGER WIRE FOOTCANDLES OF LIGHT AT A DISTANCE OF 30 INCHES FROM THE FLOOR IN: designed by: <br /> w/ , ATTACH 3 TIGHT TURNS WITHIN 1 1 UTENSIL AND EQUIPMENT STORAGE AREAS, LAVATORY AND TOILET AREAS; EKATERINA KOHLWES <br /> MEMB R WI HIN 3" OFLIGHHT TO FID FIXTURE 2) WALK-IN REFRIGERATING UNITS, DRY FOOD STORAGE AREAS AND IN OTHER AREAS; AND <br /> • CORNER. 3) DINING AREAS DURING CLEANING OPERATIONS <br /> w/ 4A TIGHITATUR A ING IN <br /> 1 1/2" 3. DURING TIMES OF CLEANIUP, ALL AREAS ARE TO HAVE A MINIMUM OF TWENTY (20) FOOT-CANDLES OF <br /> c� ® EA. END OF DIAG. WIRE ONLY LIGHT. REVISIONS: <br /> z <br /> D 4. LIGHT FIXTURES IN FOOD PREPARATION, OPEN FOOD STORAGE AND UTENSIL WASHING AREAS ARE NO DATE DESCRIPTION <br /> 045-0 TO BE OF SHATTER-PROOF CONSTRUCTION OR PROTECTED AGAINST BREAKAGE THROUGH THE USE <br /> Z OF PLASTIC LIGHT SHIELDS OR OTHER APPROVED DEVICES. <br /> 0 <br /> co <br /> 0 WIMM 5. KITCHEN CEILING SURFACES SHALL BE SMOOTH AND WASHABLE, LIGHT COLOR (LIGHT REFLECTANCE <br /> VALUE (LRV) OF 70% OR MORE.) <br /> 0 <br /> LIGHT FIXTURE--/ SUSPENDED ACOUSTICAL CEILING <br /> O PER ELEC. DWGS. TILE, PER RCP 6. EXIT AND EXIT ACCESS DOORS SHALL BE MARKED BY AN APPROVED EXIT SIGN READILY VISIBLE <br /> FROM ANY DIRECTION OF EGRESS TRAVEL WHEN TWO OR MORE EXITS ACCESSES ARE REQUIRED. <br /> MAIN RUNNER <br /> • <br /> 7. EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. TO ENSURE CONTINUED ILLUMINATION FOR A <br /> DURATION OF NOT LESS THAN 90 MINUTES IN CASE OF PRIMARY POWER LOSS, THE SIGN <br /> z 2 <br /> TYPICAL LIGHT FIXTURES SUPPORT ILLUMINATION MEANS SHALL BE CONNECTED TO AN EMERGENCY POWER SYSTEM PROVIDED A <br /> SECOND POWER SOURCE. <br /> �- OSCALE: N.T.S. <br /> 0 8. THE CEILING FINISH OVER SERVICE AREA IS SEALED TO BE SMOOTH, EASY CLEANABLE AND <br /> Z <br /> WASHABLE. <br /> c� <br /> Cn <br /> W <br /> LL <br /> I I <br /> 0 <br /> Z INDEPENDENT WIRE SUPPORT FROM THE FIXTURE HOUSING TO THE STRUCTURE ABOVE: <br /> U <br /> • PUSH FIXTURES LESS THAN 10 POUNDS, PROVIDE ONE#12 GAGE WIRE (MAY BE SLACK) <br /> FIXTURES 11 - 55 POUNDS, PROVIDE TWO#12 GAGE WIRES (MAY BE SLACK) <br /> J <br /> J - FIXTURES 56 POUNDS OR MORE SHALL BE SUPPO(ED DIRECTLY FROM THE STRUCTURE ABOVE WITHOUT <br /> zEXIT USING THE CEILING SUSPENSION SYSTEM FOR DIRECT SUPPORT <br /> 2G9 Twist on Track Light Clips 515A La In and Troffer Light Fixture 512HD Box Hanger <br /> - PENDANT HUNG FIXTURES SHALL BE SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE USING#9 GAGE <br /> 9 P Y 9 9 <br /> z0 O Support Clip WIRE <br /> 0 <br /> U BOTTOM OF <br /> Z <br /> (D <br /> C0 A.F.F., TYP. <br /> LU <br /> 0 I INDEPENDENT WIRE SUPPORT FROM THE AIR TERMINAL OR SERVICE TO THE STRUCTURE ABOVE: <br /> J <br /> O <br /> D <br /> U_ 00 <br /> p O <br /> �5 0 0 / AIR TERMINALS OR SERVICES WEIGHING 20 TO 56 POUNDS, PROVIDE TWO #12 GAGE WIRES (MAY BE <br /> G ao SLACK) <br /> • o O - AIR TERMINALS OR SERVICES WEIGHING MORE THAN 56 POUNDS SHALL BE SUPPORTED DIRECTLY TO <br /> THE STRUCTURE ABOVE <br /> +101-01, <br /> — <br /> z IDS Independent Support Clip 517 Series Light Fixture Suspension Bars SFCLT Seismic Fixture Clamp <br /> o O SUSPENDED CEILING NOTES: <br /> U � CADDY SUPPORTS LIGHTING SOLUTIONS <br /> Z <br /> O POINT TO ACCENT DINING <br /> TRACK LIGHTS 1. ALL CEILINGS SHALL USE A HEAVY DUTY T-BAR GRID SYSTEM. <br /> 101 CASHIE E 1 L 1 H T I N U P P RT PTI N <br /> o � <br /> WALL ® I 102 I A-3.V SCALE: N.T.S. 2. THE MAIN RUNNER AND/OR CROSS RUNNER ENDS SHALL BE ATTACHED TO THE PERIMETER ON TWO <br /> o O +10'-5" ADJACENT WALLS. <br /> AC.TILE 0 0 0 3. A CLEARANCE OF 3/4 INCH SHALL BE MAINTAINED BETWEEN THE MAIN RUNNER AND CROSS RUNNER <br /> 0 r ENDS AND THE PERIMETER MEMBERS ON THE TWO OPPOSITE WALLS. <br /> 0. 4. THE WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE SHALL BE NOT LESS THAN 2 INCHES. <br /> • 5. IN EACH ORTHOGONAL HORIZONTAL DIRECTION, ONE END OF THE CEILING GRID SHALL BE ATTACHED <br /> X — O 0 I TO THE CLOSURE ANGLE. <br /> '�' O O +9'-6" 6. THE OTHER END OF HORIZONTAL DIRECTION SHALL HAVE A 3/4" CLEARANCE FROM THE WALL AND Z <br /> GYP.BD. SHALL REST UPON AND BE FREE TO SLIDE ON A CLOSURE ANGLE OR LISTED ASSEMBLY. 0 <br /> 0 O 0 7. CEILING AREAS OVER 1,000SF MUST HAVE HORIZONTAL RESTRAIN WIRES (TYPICALLY RESTRAINT W <br /> U) <br /> \� WOULD CONSIST OF FOUR 12 GAUGE WIRES SPLAYED 90 DEGREES TO EACH OTHER AND SLOPED 45 0 <br /> U 1 OECESCE T LIGHTS DEGREES TO THE HORIZONTAL, SPACED 12" O.C.) LL.I <br /> Z <br /> HINES <br /> C0 M YOGURT 8. CEILING AREAS OVER 2500 SF MUST HAVE SEISMIC SEPARATION JOINTS OR FULL HEIGHT PARTITIONS <br /> o TRACK LIGHTS THAT BREAK THE CEILING INTO AREAS NOT EXCEEDING 2500 SF. <br /> LL <br /> POINT TO TO PIN(s % ' % % % % % % % ' % % % % % % 9. EXCEPT WHERE RIGID BRACES ARE USED TO LIMIT LATERAL DEFLECTION, SPRINKLER HEADS AND (n <br /> o CONTAINERS <br /> OTHER PENETRATIONS THROUGH THE CEILING TILE REQUIRE MINIMUM 2-INCH RINGS, SLEEVES OR LU <br /> ADAPTERS THAT WILL ALLOW A MINIMUM 1-INCH CEILING MOVEMENT IN ALL HORIZONTAL DIRECTIONS. cl: <br /> ALTERNATIVELY, A SWING JOINT CAN BE PROVIDED AT THE TOP OFTHE SPRINKLER HEAD EXTENSION TO O <br /> • Dn ' ' ' ' ' ' ' ' ' ' ' ' ' ' ACCOMMODATE THE 1-INCH MOVEMENT. <br /> � � zzzzzzz ' zizzzzz ' iizzzz <br /> J <br /> % % % '/. % % % % % % '/. % % % % % % '/. % % % % '/. <br /> Z <br /> _DnJ <br /> z JQ <br /> 0 _KLT C ; ; ; <br /> Z LU <br /> ILL V <br /> LU <br /> +10'-5 REFLECTED CEILING LEGEND U J <br /> � <br /> AC.TILE z z z � z z3 <br /> o I LL F L1I <br /> SYMBOL DESCRIPTION <br /> • W N U <br /> Z z N <br /> U <br /> EXIT EXISTING EXIT SIGN W/EMERGENCY BACKUP (� <br /> O Q Q W <br /> SUPPLY DIFFUSER IN CEILING TILE OF GYP.BD. (REFER TO MECHANICAL DRAWINGS)0 <br /> W <br /> > IDQ V <br /> Z ii , iiiiiii i ilii ' i ilii ' i ii <br /> Joz <br /> z 2X2 RETURN DIFFUSER(REFER TO MECHANICAL DRAWINGS FOR 0 0 0 W <br /> iiiiiii iiiiiii ' / / 000i ' iiiiii LOCATION J <br /> LU iii i l i i i i i i i i i ' i i i i i i i ' i i i i i i O <br /> 0 <br /> J +9'-6" Lzzzzzzz iizzzzz zzzzzzz iizzzzU <br /> U_ GYP.BD. EXHAUST FAN PER MECHANICAL DRAWINGS, FROM TAZZ LIGHTING, INC, CONTACT MARTIN EPSTEIN <br /> 0 <br /> o 0 o <br /> Z 0 760-522-1964 <br /> ILL ;I <br /> W <br /> — <br /> U) <br /> 0- <br /> DI ESTROOM <br /> • � � � � � � � � � � � � � � � ' � � � � � � ' � � � � � � T TRACK LIGHTING,WHITE FINISH, FROM TAZZ LIGHTING, INC, CONTACT MARTIN EPSTEIN 760-522-1964 <br /> 104 <br /> J <br /> J <br /> LUQ/ <br /> WATER DROP HANGING LIGHT DECORATIVE PENDANT, CONTACT MARTIN EPSTEIN 760-522-1964 <br /> z ' a a a z a z �Frozen Yogurt,Ice-Cream and More... <br /> � XIT <br /> Z <br /> 0 <br /> U <br /> Z ® DECORATIVE MULTI COLOR PENDANT LIGHT, CONTACT MARTIN EPSTEIN 760-522-1964 <br /> c� <br /> Cn <br /> w <br /> DATE 11 /10/2020 <br /> o LED GIMBAL RECESSED DOWNLIGHT, WHITE FINISH, FROM TAZZ LIGHTING, INC, CONTACT MARTIN <br /> EPSTEIN 760-522-1964 SCALE NOTED <br /> U <br /> NORTH LED RECESSED DOWNLIGHTS,ALCON MODEL 14013-P, WHITE FINISH, FROM TAZZ LIGHTING, INC, DRAWN E.K. <br /> O CONTACT MARTIN EPSTEIN 760-522-1964 <br /> REFLECTED CEILING PLAN JOB # 2013 <br /> 0 2X4 LED TROFFER -COLUMBIA MODEL LJT22 OR SIMILAR AND SURFACE MOUNTED ALCON MODEL <br /> z <br /> SCALE: 1/4"=V-0" 11151 OR SIMILAR, FROM TAZZ LIGHTING, INC, CONTACT MARTIN EPSTEIN 760-522-1964 SHEET NO. <br /> Z <br /> 0 <br /> U <br /> Z ACOUSTICAL CEILING TILE-2X4 <br /> C0 <br /> z z z z z z z z z z z A� 300 <br /> U_ <br /> z z z z e a z z i z z <br /> 2X4 INDUSTRIAL KITCHEN RATED CEILING TILE, SMOOTH AND WASHABLE <br /> G <br />
The URL can be used to link to this page
Your browser does not support the video tag.