Laserfiche WebLink
SAN J OA U I Environmental Health Department <br /> COUNTY <br /> — <br /> Hazardous Materials Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CONTI MATERIAL SVC LLC 3932 NEWTON RD, STOCKTON June 08, 2021 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 5 HSC 25505(a)(1) Failed to electronically submit hazardous materials inventory for all reportable materials on site. <br /> OBSERVATION: One 750 gallon tank of diesel exhaust fluid, one 275 gallon waste oil tank, and one 275 gallon <br /> waste antifreeze tote were found on site that have not been reported to CERS. <br /> REGULATION GUIDANCE: Any material that meets or exceeds the reportable quantity shall be reported in the <br /> facility's business plan. <br /> CORRECTIVE ACTIONS: Immediately log into the California Environmental Reporting System (CERS) at <br /> http://cers.calepa.ca.gov/, add the materials to the hazardous material inventory, and submit to the EHD for <br /> approval. <br /> This is a repeat violation, Class Il. <br /> 6 HSC 25505(a)(2) Failed to electronically submit a site map with all required content. <br /> OBSERVATION: The site map is incomplete. The site map does not show/address the following required elements: <br /> 1. Loading areas. <br /> 2. Internal roads. <br /> 3. Access and exit points (structure). <br /> 4. Emergency response equipment (fire extinguishers and spill control). <br /> 5. Emergency shutoff (diesel). <br /> 6. The locations/actual locations of compressed oxygen, acetylene, waste oil, new oil, ZEP cleaner and truck <br /> wash, transmission fluid, argon/carbon dioxide mixture, sulfuric acid, antifreeze, waste antifreeze, potassium <br /> hydroxide, diesel exhaust fluid, and sodium hyphochlorite. <br /> 7. A legend to define codes/abbreviations used on the map has not been provided (FE, FEE, SCE, LTS,00, 2 , 5, <br /> 6, STMD, SEWD) <br /> REGULATION GUIDANCE: A site map shall contain a north orientation, loading areas, internal roads, adjacent <br /> streets, storm and sewer drains, access and exit points, emergency shutoffs, evacuation staging areas, hazardous <br /> material handling and storage areas, and emergency response equipment. <br /> If a site map element is not applicable for your facility then list it on the map and label as "NA". <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS)at <br /> http://cers.calepa.ca.gov/, upload the correct or updated information, and submit to the EHD for approval. <br /> This is a repeat violation, Class Il. <br /> FA0010885 PR0520535 SCO01 06/08/2021 <br /> EHD 19-01 Rev.9/16/2020 Page 2 of 5 Hazardous Materials Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />