Laserfiche WebLink
Il�)�CEIIVED <br />Appendix V1 NOV 0 5 2018 <br />(Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at htt ://www,waterboards.ca. ov. <br />ENVIRONNIENVAL EALT11 <br />MONITORING SYSTEM CERTIFICATION [DEPARTMENT <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of <br />Regulations <br />This form must <br />be used to document <br />testing <br />and servicing of monitoring equipment. <br />A separate <br />certification or <br />report must be prepared for <br />each monitoring <br />system control panel <br />by the <br />technician who performs the work. A <br />copy of this <br />form must be <br />provided to the tank system <br />owner/operator. <br />The owner/operator must submit a copy of this form to the local agency regulating <br />UST systems <br />within 30 days of test date. <br />A. Generallnformation <br />Facility Name: _Ramos Oil Company Bldg. No.: <br />site Address: _10842 S. Harlan Road city: _French Camp zip: <br />Facility Contact Person: _Steve RlChardSOn Contact Phone No.:916-371-2570 <br />Make/Model of Monitoring System: _TLS -35O Date of Testing/Servicing: _1 O/25�18 <br />B. Inventory of Equipment Tested/Certified <br />'Ii the facility contains more tanks or dispensers, copy this form. Include information for every <br />Check the appropriate boxes <br />to indicate <br />specific a uipment ins <br />ected/serviced: <br />Tank ID: Diesel <br />Tank ID: <br />x <br />_1 <br />In -Tank Gauging Probe. <br />Model: <br />1 <br />❑ <br />In -Tank Gauging Probe. <br />Model <br />x <br />Annular Space or Vault Sensor. <br />Model: <br />_Mag <br />303 <br />❑ <br />Annular Space or Vault Sensor. <br />Model: <br />x <br />Piping Sump /Trench Sensor(s). <br />Model: <br />_VR <br />VR 208 <br />❑ <br />Piping Sump / Trench Sensor(s). <br />Model: <br />x <br />Fill Sump Sensor(s). <br />Model: <br />VR 208 <br />❑ <br />Fill Sump Sensor(s). <br />Model: <br />x <br />Mechanical Line Leak Detector. <br />Model: <br />LD 2000 <br />❑ <br />Mechanical Line Leak Detector. <br />Model: <br />❑ <br />Electronic Line Leak Detector. <br />Model: <br />_VMI <br />❑ <br />Electronic Line Leak Detector. <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor. <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor. <br />Model - <br />odel:Others <br />Other (seci equipment t e and <br />model in Section E on Page 2). <br />t_1Other <br />(specify equipment type and model <br />in Section <br />E on Page 2), <br />Tank ID: <br />Tank ID: <br />❑ <br />In -Tank Gauging Probe. <br />Model: <br />❑ <br />In -Tank Gauging Probe. <br />Model: <br />❑ <br />Annular Space or Vault Sensor. <br />Model: <br />❑ <br />Annular Space or Vault Sensor. <br />Model: <br />❑ <br />Piping Sump / Trench Sensor(s). <br />Model: <br />❑ <br />Piping Sump/ Trench Sensor(s). <br />Model: <br />❑ <br />Fill Sump Sensor(s). <br />Model: <br />❑ <br />Fill Sump Sensor(s). <br />Model: <br />❑ <br />Mechanical Line Leak Detector. <br />Model: <br />❑ <br />Mechanical Line Leak Detector. <br />Model: <br />❑ <br />Electronic Line Leak Detector. <br />Model: <br />❑ <br />Electronic Line Leak Detector. <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor. <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor. <br />Model: <br />❑ <br />Other(specify equipment t e and <br />model in Section E on Page 2), <br />❑ <br />Other(specify equipment t e and model <br />in Section <br />E on Page 2), <br />Dispenser <br />ID: _1-2 <br />Dispenser ID: _3-4 <br />x <br />Dispenser Containment Sensor(s). <br />Model: <br />_VR 208 <br />x <br />Dispenser Containment Sensor(s). <br />Model: <br />208 <br />❑ <br />Shear Valve(s). <br />❑ <br />Shear Valve(s). <br />_VR <br />❑ <br />Dispenser Containment Floats and <br />Chain(s), <br />❑ <br />Dispenser Containment Float(s) and <br />Chain(s). <br />Dispenser ID: _Satellite 1 <br />Dispenser ID: _Satellite 4-5 <br />x <br />Dispenser Containment Sensor(s). <br />Model: <br />_VR 208 <br />x <br />Dispenser Containment Sensor(s). <br />Model: <br />208 <br />❑ <br />Shear Valve(s).❑ <br />Shear Valve(s). <br />_VR <br />11Dispenser <br />Containment Floats and <br />Chain(s). <br />❑ <br />Dispenser Containment Floats and <br />Chain(s). <br />Dispenser <br />ID: _Satellite _2-3 <br />Dispenser ID: _5 <br />x <br />Dispenser Containment Sensor(s). <br />Model: <br />_VR 208 <br />x <br />Dispenser Containment Sensor(s). <br />Model: 208 <br />❑ <br />Shear Valve(s). <br />❑ <br />Shear Valve(s). <br />_VR <br />❑ <br />Dispenser Containment Floats and Chains <br />❑ <br />Dispenser Containment Float(s) and <br />Chain(s). <br />tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspectedlserviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification are information (e.g. manufacturers' checklists) necessary to verify that this information is correct <br />and a Plot Plan showing the layout of monitoring equipment For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that apply): ❑ System set-up ❑ Alarm histgDf. report y <br />Technician Name (print): Gabe Garcia <br />Certification No.: B42919 <br />Testing Company Name: _JP PetroleUm SerVICe <br />Signature: <br />License. No.: 811471 <br />Phone No.:(_916�_372-5693 <br />Testing company Address: 3065 Asante Lane, W. Sacto Ca 95691 <br />Monitoring System Cert <br />ification <br />Page 1 of 4 <br />1 <br />Date of Testing/Servicing: _10-25-18 <br />12107 <br />