Laserfiche WebLink
A NJ O A Q U l N Environmental Health Department <br /> COUNTY— <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Eleventh Street Chevron 7501 W ELEVENTH ST,Tracy June 28, 2021 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 604 CFR 112.7(a)(3)(i)Plan failed to include oil type and storage capacity for each container. <br /> OBSERVATION: The Spill Prevention, Control, and Countermeasure(SPCC)Plan failed to address the type of oil <br /> and storage capacity for each fixed container. <br /> -Table G-2 of the SPCC Plan lists one 12,000-gallon diesel/gas fuel tank, but one 6,000-gallon diesel and one <br /> 6,000-gallon gasoline split tank was observed on site. <br /> -Table G-2 of the SPCC Plan lists one 650-gallon 3 compartment motor oil tank, but the plan does not include how <br /> big each compartment is. <br /> REGULATION GUIDANCE: The SPCC plan shall include: (i)The type of oil in each fixed container and its storage <br /> capacity. For mobile or portable containers, either provide the type of oil and storage capacity for each container or <br /> provide an estimate of the potential number of mobile or portable containers,the types of oil, and anticipated <br /> storage capacities. <br /> CORRECTIVE ACTION: Ensure the SPCC Plan properly addresses the type and storage capacity of all fixed and <br /> portable and/or mobile containers, as required. Submit proof of correction to the EHD. <br /> This is a repeat violation, Class II. <br /> 609 CFR 112.7(a)(3vi), 112.7(a4)Plan failed to adequately contain procedures for reporting a discharge. <br /> OBSERVATION: The Spill Prevention, Control, and Countermeasure(SPCC) Plan does not adequately discuss <br /> procedures for reporting a discharge.Two places in the SPCC plan had an incorrect phone number for Cal OES <br /> (916-845-8510). <br /> REGULATION GUIDANCE: The SPCC plan shall include: (vi)Contact list and phone numbers for the facility <br /> response coordinator, National Response Center, cleanup contractors with whom you have an agreement for <br /> response, and all appropriate Federal, State, and local agencies who must be contacted in case of a discharge as <br /> described in § 112.1(b). <br /> (4)Unless you have submitted a response plan under§ 112.20, provide information and procedures in your Plan to <br /> enable a person reporting a discharge as described in § 112.1(b)to relate information on the exact address or <br /> location and phone number of the facility;the date and time of the discharge,the type of material discharged; <br /> estimates of the total quantity discharged; estimates of the quantity discharged as described in§ 112.1(b);the <br /> source of the discharge; a description of all affected media;the cause of the discharge; any damages or injuries <br /> caused by the discharge; actions being used to stop, remove, and mitigate the effects of the discharge;whether an <br /> evacuation may be needed; and, the names of individuals and/or organizations who have also been contacted. <br /> CORRECTIVE ACTION: Immediately ensure the SPCC Plan includes the correct phone number for Cal OES. <br /> Submit proof of correction to the EHD. <br /> This is a repeat violation, Class ll. <br /> FA0022384 PR0539001 SCO01 06/28/2021 <br /> EHD 28-01 Rev.9/16/2020 Page 6 of 11 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />