My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4855
>
2300 - Underground Storage Tank Program
>
PR0506650
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:15 PM
Creation date
7/7/2021 9:13:37 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0506650
PE
2361
FACILITY_ID
FA0007571
FACILITY_NAME
ARCH ARCO AM PM*
STREET_NUMBER
4855
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
APN
17926051
CURRENT_STATUS
01
SITE_LOCATION
4855 S HWY 99
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM ( Page 1 of 1 ) <br /> Type of Action ❑ Installation Inspection ❑ Repair Inspection ❑x 36 Month Inspection <br /> I . FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 2/7/2019 <br /> 10182251 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) <br /> ARCH ROAD AM / PM <br /> Business Site Address City ZIP Code <br /> 4855 S . HIGHWAY 99 ISTOCKTON 95205 <br /> II . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as shown on the /CC Certification.) Phone # <br /> Zane Nimmo (209 ) 744- 0112 <br /> Contractor / Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 04- 1676 Ex . 03/31 /2019 8883064- UT 6/ 1 /2019 <br /> Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications.) <br /> FF- EBW , PhikTite & EVR Phase 1 10009843708 Ex 11 -29-20 OPW 104-632 Ex 3- 14-2020 <br /> Emco 3206 Ex . 11 / 14/2020 ATG : VR : A28446 Ex . 9/28/ 19 Incon # 1009843708 Ex . 11 -30-221 <br /> III . OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method ❑x Manufacturer Guidelines (Specify) : MAR I209 <br /> Used : VEEDER ROOT TLS PROBE TESTING <br /> ❑ Industry Code or Engineering Standard (Specify) : <br /> TH <br /> ❑ Engineered Method (Specify): <br /> Attach the inspection procedures and all documentation required to determine the results. --r#-of Attached Pages 5 <br /> TANK ID : (By tank number, storedproduct, etc.) 1 - 87 OCT 2 - 89 OCT 3 - 91 OCT <br /> What is the tank inside diameter? (Inches) 117 . 5 117 . 5 117 . 5 <br /> Is the fill piping secondarily contained? Zx Yes Z No x❑ Yes ❑ No ❑x Yes ❑ No ❑ Yes ❑ No <br /> Is the vent piping secondarily contained? ❑ Yes 9 No Z Yes ❑x No Z Yes ❑x No ❑ Yes Z No <br /> Overfill Prevention Equipment Manufacturer(s) V R VR V R <br /> What is the overfill prevention equipment response Z Shuts Off Flow ❑ Shuts Off Flow ❑ Shuts Off Flow ❑ Shuts Off Flow <br /> when activated ? <br /> (Check all that apply.) ❑ Restricts Flow ❑ Restricts Flow ❑ Restricts Flow ❑ Restricts Flow <br /> Z A/V Alarm ❑x A/V Alarm ❑ AIV Alarm ❑ AIV Alarm <br /> Are flow restrictors installed on vent piping ? ❑ Yes ❑x No Z Yes ❑x No Z Yes R No Z Yes ❑ No <br /> At what level in the tank is the overfill prevention set <br /> to activate? (Inches from bottom of tank.) 98 . 5° 98 . 0 ° 97 . 5 ° <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? 90 % 90 % 90 % <br /> Is the overfill prevention in proper operating condition ❑K Yes ❑x Yes ❑x Yes ❑ Yes <br /> to respond when the substance reaches the <br /> appropriate level ? ❑ No (Specify in V.) ❑ No (Specify in V.) ❑ No (Specify in V) ❑ No (Specify in V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results ❑x Pass ❑ Fail I ❑x Pass ❑ FeCiFTZ Pass ❑ Fail j ❑ Pass ❑ Fail <br /> V. COMMENTS <br /> Any items marked "Fail" must be explained in this section. Any additional comments may also be provided here . <br /> VI . CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipmentwas inspected in accordance with California Code of Regulations , Title 23 , <br /> Division 3 , Chapter 16 , Section 2637 . 2 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> If the facility has more components than this form accommodates, additional copies of this page may be attached. <br /> CERS = California Environmental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = International Code Council, A/V = Audible and Usual <br />