Laserfiche WebLink
Environmental Health Department <br />Time In: <br /> 1:31 pm <br /> 1:05 pm <br />Time Out: <br />Program Element: 3699 - POOL/SPA - OUT OF SERVICE <br />Telephone: (209) 688-0029 Owner/Operator: MORFORD, SHARON LEE <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 12404 N HWY 99 , LODI 952407229 <br />Date: 07/06/2021Name of Facility: MARIONS RANCH HOUSE MOTEL <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #2 Pool Enclosure <br />OBSERVATIONS: There areas where the fence material seem to be loose. Tighten the fence material so that the pool are <br />is not accessible through the fence. <br />CALCODE DESCRIPTION: Pool area shall be enclosed by one or more of the following: a fence, portion of a building, wall, or other <br />approved durable enclosure. Pool enclosure shall be constructed over a hard permanent material equivalent to concrete and shall be <br />installed no more than 2 inches above the finished grade. Holes, gaps, or openings in the enclosure shall not allow the passage of a <br />4-inch diameter sphere. Doors, openable windows, or gates of living quarters shall not be permitted as part of the pool enclosure. (CBC <br />3119B) Pool operator shall keep the pool enclosure well maintained. (CCR 65535) Pool enclosure shall have a minimum effective <br />perpendicular height of 5 feet and shall be constructed so that it cannot be climbed by small children. Horizontal members shall be spaced <br />at least 48 inches apart. No planters or other climbable structures shall be permitted within 5 feet of the pool enclosure or within a 5-foot <br />arc. Chain link openings shall not be larger than 1 3/4 inches when measured horizontally. Pool enclosures with a height of 4 or more feet <br />are allowed if the enclosure was constructed prior to July 1994. (CBC 3119B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F <br />Combined chlorine:ppm <br />NOTES <br />The pool kept locked with padlock. The pool is empty. <br />continue to maintain the pool free of hazards. <br />The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br />Safety Code. If a reinspection is required, fees will be assessed at the current hourly rate. <br />Received by: Name and Title: <br />EH Specialist:Phone: <br />, <br />VIDAL PEDRAZA <br />Page 1 of 1EHD 36-01 Rev. 06/30/15 Swimming Pool OIR <br />FA0000334 PR0360631 SC001 07/06/2021 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjcehd.com