Laserfiche WebLink
SAN JOAQUIN <br />COUNTY- <br />l-ᅵuolofss grows hcrc. <br />Environmental Health Department <br />Swimming Pool Official Inspection Report <br />Time In: 1-19pm <br />Time Out: 135 pin <br />Name of Facility: LAKESHORE MEADOWS APTS SOUTH <br />Date: 06/11/2020 <br />Address: 2080 SYLVAN WAY, LODI 95242 <br />Owner/Operator: LAKESHORE MEADOWS APTS <br />Telephone: (209) 369-0734 <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Inspection Type: ROUTINE INSPECTION - Operating Permit Reinspection on or after: 06/25/2020 <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, $ <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR"pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br />94 Safety Equipment MAJOR <br />OBSERVATIONS: Observed life ring tangle and not properly display for access. (Corrected on site). <br />CALCODE DESCRIPTION., Safety equipment shall be provided, maintained, readily visible, and available for use. Pools shall have at <br />minimum one 12 foot tlxed-length rescue pole with a permanently attached body hook and one 17 -inch life ring with an attached throw <br />rope. Throw rope shall be of sufficient length to span the maximum width of the pool and shall be stored to prevent kinking or fouling. <br />(CCR 65540) <br />#8 Pool and Deck Lighting <br />OBSERVATIONS: Observed GFCI is non-functional. Repair immediately. <br />CALCODE DESCRIPTION: Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br />pool. When a pool is used at night, pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br />not operational, the pool operator shall post a sign in 4 -inch letters stating 'NO USE OF POOL ALLOWED AFTER DARK" and shall <br />secure the pool area and not permit any use of the pool after dark. (3115B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate: 50 gpm <br />Cyanuric acid: <30 ppm <br />NOTES <br />Routine Inspection <br />Influent: 18 <br />Effluent: 10 <br />Pool Closure Issued <br />Chlorine: 4.8 ppm <br />pH: 7.2 <br />of <br />Combined chlorine: ppm <br />Observed GFCI is non-functional. Contact Jeff Carruessco or Vidal Pedraza prior to opening. <br />The person in charge Is responsible for ensuring that the above mentioned facility is In compliance with all applicable sections of the California Health and <br />Safety Code. If a reinspection is required, fees will be assessed at the cement hourly rete. <br />Received by: <br />Name and Title: <br />EH Specialist: KRISTINA SAETERN Phone: (209) 468-9438 <br />FA0000672 PR0360560 SCO01 06/11/2020 <br />EHD 36-01 Rev. 06/30/15 Page 1 of 1 Swimming Pool OIR <br />