Laserfiche WebLink
Environmental Health Department <br />Time In: <br /> 2:00 pm <br /> 1:30 pm <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: Owner/Operator: RPM COMPANY <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 4777 GROUSE RUN DR, STOCKTON 95207 <br />Date: 07/12/2021Name of Facility: SOUTH SHORE APARTMENTS <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #4 Safety Equipment <br />OBSERVATIONS: Life ring is available but is missing the attached rope. Attach a rope to the life ring immediately. Will re <br />inspect to verify rope has been attached to the life ring. <br />CALCODE DESCRIPTION: Safety equipment shall be provided, maintained, readily visible, and available for use. Pools shall have at <br />minimum one 12 foot fixed-length rescue pole with a permanently attached body hook and one 17-inch life ring with an attached throw <br />rope. Throw rope shall be of sufficient length to span the maximum width of the pool and shall be stored to prevent kinking or fouling. <br />(CCR 65540) <br /> #35 Flow Meters <br />OBSERVATIONS: Flow meter reading is 0. Flow meter appears to not be working. Install flow meter. <br />CALCODE DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br /> #38 Filter Cleaning and Maintenance <br />OBSERVATIONS: Gauges pressure between influent and effluent is greater than 10 psi. A change of filter may be needed. <br />CALCODE DESCRIPTION: All filters shall be maintained in accordance with manufacturer's specifications. (CBC 3123B) Pressure gauge <br />located on the filter shall be marked with the clean startup reading. (CBC 3125B) Each filter vessel shall be provided with valves so that it <br />can be isolated from the recirculation system for repairs and backwashing. (CBC 3128B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F 0 <br />7.8 <br />3.0 <br />less than 30 Combined chlorine:ppm <br />NOTES <br />Influent: 25 psi <br />Effluent: 4 psi <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0002622 PR0360133 SC001 07/12/2021 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD