Laserfiche WebLink
Department of Public Works <br /> z SAN JOAQUIN <br /> {� COUNTY 3, t Kris Balaji,Director of Public Works <br /> Fritz Buchman,Deputy Director/Development <br /> Greatnessrows here. <br /> 9 W�]d� for YOU David Tolliver,Deputy Director/Operations <br /> -- - <br /> Najee Zarif,Deputy Director/Engineering <br /> Kristi Rhea,Business Administrator <br /> November 15, 2021 -- <br /> MEMORANDUM <br /> TO: Community Development Department <br /> CONTACT PERSON: Giuseppe Sanfilippo <br /> FROM: Christopher Heylin, Development Services Engineer <br /> Development Services Division <br /> SUBJECT: PA-1700279; A Site Approval application for the construction, operation, and <br /> decommissioning of the North Central Valley Energy Center Project consisting of a 132- <br /> megawatt battery energy storage system (BESS) on approximately 14.85 acres of a <br /> 57.28-acres parcel, which would include up to (300) battery storage containers (totaling <br /> up to 45,000 square feet) and associated on-site support facilities including an 11,000 <br /> square-foot Project collector substation, up to (50) inverters (totaling up to 6,500 square <br /> feet), collector lines, fencing, access roads, an operations and maintenance building, a <br /> supervisory control and data acquisition (SCADA) system, and other ancillary facilities <br /> and equipment. Approximately (17) of the proposed inverters would include screening <br /> barriers for the purpose of attenuating inverter noise, should all inverters operate at <br /> maximum capacity. The screening barriers would be approximately 14 feet tall with <br /> respect to grade. The Project also includes (2) power poles and a 115-kilovolt overhead <br /> generation transmission line to connect the BESS to the adjacent Pacific Gas and <br /> Electric Bellota Substation. A 1.52-acre expansion of the Bellota Substation footprint <br /> would also be required to support grid interconnection of the Project; located on the <br /> south side of Flood Road, 0.8 miles west of Escalon-Bellota Road, Linden. <br /> (Supervisorial District 4) <br /> OWNER: William Earl Jr. & Marilyn Van Tassel APPLICANT: North Central Valley Energy <br /> Storage, LLC <br /> ADDRESS: 24300 E. Flood Road, Linden APN: 093-100-20 & -24 <br /> INFORMATION: <br /> The site is not currently located within a Federal Emergency Management Agency Designated Flood <br /> Hazard Area. <br /> Flood Road has an existing right-of-way width of 40 feet and a planned right-of-way width of 50 feet. <br /> 1810 East Hazelton Avenue I Stockton, California 95205 1 T 209 468 3000 1 F 209 468 2999 <br /> Follow us on Facebook @ PublicWorksSJC Visit our website: www.sjgov.org/pubworks <br />