Laserfiche WebLink
July 14, 2021 Lab ID : STK2138920 <br />San Joaquin Co. Environmental Health Dep Customer : 3-17919 <br />Quality Control - Inorganic <br />Constituent Method Date/1D Type Units Conc. QC Data DQO Note <br />Wet Chem <br />Nitrate 300.0 (V12144773-002) MSD mg/L 40.00 103% 85-119 <br />MSRPD mg/L 10.00 0.9% <19 <br />300.0 06/25/21:209708MCA ICB mg/L 0.000 0.5 <br />ICV mg/L 20.00 98.6% 90-110 <br />CCB mg/L 0.000 0.5 <br />CCV mg/L 20.00 98.3% 90-110 <br />Nitrate + Nitrite as N 300.0 06/25/21 :207151MCA Blank mg/L ND <0.1 <br />Nitrate Nitrogen 300.0 06/25/21 :207151MCA Blank mg/L ND <0.1 <br />Nitrite 300.0 06/25/21 :207151MCA Blank mg/L ND <0.5 <br />LCS mg/L 15.00 103% 90-110 <br />MS mg/L 30.00 103% 74-126 <br />(V12144773-001) MSD mg/L 30.00 104% 74-126 <br />MSRPD mg/L 10.00 1.1% 20 <br />MS mg/L 30.00 102% 74-126 <br />(V12144773-002) MSD mg/L 30.00 103% 74-126 <br />MSRPD mg/L 10.00 1.2% 20 <br />300.0 06/25/21:209708MCA ICB mg/L 0.000 0.5 <br />ICV mg/L 15 00 100% 90-110 <br />CCB mg/L 0.000 0.5 <br />CCV mg/L I 5(t) 99.7% 90-110 <br />Nitrite Nitrogen 300.0 06/25/21:207151MCA Blank mg/L ND <0.2 <br />Sulfate 300.0 06/25/21:207151MC A Blank mg/L ND <0.5 <br />LCS mg/L 50.00 103% 90-110 <br />MS mg/L 100.0 101% 82-124 <br />(V12144773-001) MSD mg/L 100.0 103% 82-124 <br />MSRPD mg/L 10.00 1.2% 23 <br />MS mg/L 100.0 101 % 82-124 <br />(VI 2144773-002) MSD mg/L 100.0 100% 82-124 <br />MSRPD mg/L 10.00 0.6% 23 <br />300.0 06/25/21:209708MCA ICB mg/L 0.000 0.5 <br />ICV mg/L 50.00 99.5% 90-110 <br />CCB mg/L 0.193 0.5 <br />CCV mg/L 50.00 99.7% 90-110 <br />N1BAS 5540C 06/25/21:210243JBA CCB mg/L -0.0393 0.25 <br />CCV mg/L 1.000 109% 90-110 <br />CCB mg/L -0.0393 0.25 <br />CCV mg/L 1.000 106% 90-110 <br />MBAS Extraction 5540C 06/25/21:207589JBA Blank mg/L ND <0.1 <br />LCS mg/L 0.5000 106% 86-114 <br />BS mg/L 0.5000 110% 86-114 <br />BSD mg/L 0.5000 110% 86-114 <br />BSRPD mg/L 0.5000 0.8% <5 <br />Definition <br />ICV : Initial Calibration Verification - Analyzed to verify the instrument calibration is within criteria. <br />ICB : Initial Calibration Blank - Analyzed to verify the instrument baseline is within criteria. <br />CCV : Continuing Calibration Verification - Analyzed to verify the instrument calibration is within criteria. <br />CCB : Continuing Calibration Blank - Analyzed to verify the instrument baseline is within criteria. <br />Blank : Method Blank - Prepared to verify that the preparation process is not contributing contamination to the samples. <br />LCS : Laboratory Control Standard/Sample - Prepared to verify that the preparation process is not affecting analyte recovery. <br />MS : Matrix Spikes - A random sample is spiked with a known amount of analyte. The recoveries are an indication of how that sample <br />matrix affects analyte recovery. <br />MSD : Matrix Spike Duplicate of MS/MSD pair - A random sample duplicate is spiked with a known amount of analyte. The recoveries <br />are an indication of how that sample matrix affects analyte recovery. <br />BS : Blank Spikes - A blank is spiked with a known amount of analyte. It is prepared to verify that the preparation process is not <br />affecting analyte recovery. <br />Page 8 of 9