Laserfiche WebLink
Environmental Health Department <br />Time In: <br />10:10 am <br /> 9:20 am <br />Time Out: <br />Program Element: 3612 - PUBLIC POOL/SPA - ADDITIONAL <br />Telephone: (209) 334-6988 Owner/Operator: MUNSON, RUSS <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 2505 W TURNER RD, LODI 95242 <br />Date: 07/01/2021Name of Facility: WINE & ROSES HOTEL RESTAURANT SPA <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #25 Spa Emergency Shut Off Switch MAJOR <br />OBSERVATIONS: Emergency Shut off does not function properly. <br />When shut off is button is pressed there is still suction occurring in the skimmers. <br />Provide so that the Emergency Shut off shuts off the jets and the pump completely. <br />CALCODE DESCRIPTION: A clearly labeled emergency shut off switch for both the spa recirculation and jet/aeration systems shall be <br />installed adjacent to the spa pool. (CBC 3138B) <br /> #8 Pool and Deck Lighting <br />OBSERVATIONS: Spa light is not functional. <br />Provide functional light and GFI <br />CALCODE DESCRIPTION: Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br />pool. When a pool is used at night, pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br />not operational, the pool operator shall post a sign in 4-inch letters stating "NO USE OF POOL ALLOWED AFTER DARK" and shall <br />secure the pool area and not permit any use of the pool after dark. (3115B) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: Large o-ring and weir are lacking for skimmer. <br />Provide <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F <br />7.6 <br />3.8 <br />60 <br /> 102.00 <br />Combined chlorine:ppm <br />NOTES <br />Spa Is Closed <br />West Spa <br />Operator to call for re-inspection to re-open spa <br />Page 1 of 2EHD 36-01 Rev. 06/30/15 Swimming Pool OIR <br />FA0012707 PR0526187 SC001 07/01/2021 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjcehd.com