Laserfiche WebLink
Environmental Health Department <br />Time In: <br />10:17 am <br /> 9:23 am <br />Time Out: <br />Program Element: 3616 - PUBLIC POOL/SPA - EXEMPT <br />Telephone: (209) 830-3200 Owner/Operator: TRACY UNIFIED SCHOOL DISTRICT <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 315 E ELEVENTH ST, TRACY 95376 <br />Date: 07/22/2021Name of Facility: TRACY USD-JOINT UNION HIGH <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #10 Disinfectant Residual MAJOR <br />OBSERVATIONS: The chlorine level of the dive pool is 1.6ppm. Immediately adjust the chlorine level of the dive pool to <br />2.0-10.0 ppm or face closure. <br />Chlorinator turned on: re-checked chlorine level at 4.2 ppm at the end of the inspection. <br />Corrected on site. <br />CALCODE DESCRIPTION: Public pools, when open or in use, shall be disinfected continuously by approved chemicals and shall maintain <br />the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br />or 2.0 ppm bromine. Spas, wading pools, and spray grounds shall maintain the following concentrations: 3.0 ppm to 10.0 ppm free <br />chlorine or 4.0 ppm bromine. (CCR 65529) <br /> #3 Safety Signs <br />OBSERVATIONS: The diarrhea notice signage is faded. Replace diarrhea notice signage by 1 week. <br />CALCODE DESCRIPTION: Pool operator shall keep safety signs well maintained. (CCR 65535) Safety signs shall have clearly legible <br />letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall, pole, gate, or similar <br />permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br /> #8 Pool and Deck Lighting <br />OBSERVATIONS: Two of the lights in the dive pool are burned out. Repair/replace lights by 2 weeks. <br />The lights will not turn back on after the GFI is reset at the electrical panel. Repair ASAP. <br />CALCODE DESCRIPTION: Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br />pool. When a pool is used at night, pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br />not operational, the pool operator shall post a sign in 4-inch letters stating "NO USE OF POOL ALLOWED AFTER DARK" and shall <br />secure the pool area and not permit any use of the pool after dark. (3115B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F 431 <br />7.4 <br />1.6 <br /><30 Combined chlorine:ppm0.0 <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0002996 PR0360154 SC001 07/22/2021 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD