Laserfiche WebLink
SAN AQUI N Environmental Health Department <br /> " . <br /> `! COU NTY- - <br /> Linda Turkatte, RENS, Director <br /> Greatness grows here. Kasey Foley, REHS,Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellon, REHS <br /> Jeff Carruesco, RENS, RDI <br /> Steven Shih, REHS <br /> Willy Ng, REHS <br /> Muniappa Naidu, REHS <br /> 07/30/2021 <br /> Giannecchini, Renee Joyce <br /> 7160 N Wall Rd <br /> Linden, CA 95236 <br /> RE: Well Pump Inspection <br /> Well Location: 16925 Comstock Rd, Linden Permit#: WP0041922 Inspection Date: 7/28/2021 <br /> The Environmental Health Department recently conducted a water well pump inspection at the above address <br /> and found the following issues at the time of the inspection. In order to protect the ground water supply and <br /> your water source from potential degradation, please take the associated corrective actions. <br /> ❑ Lack of or Inadequate Concrete Platform around Wellhead. <br /> (SJC Well Standards, Section 4.10.—Surface Seal) <br /> Corrective Action: Repair existing or install a new concrete platform around the wellhead that <br /> extends two feet in all directions from the well casing. <br /> ❑ Lack of or Inadequate Sanitary Seal at Wellhead. <br /> (SJC Ord. Code, Title 9, Section 9-1115.5. —Well Regulations) <br /> Corrective Action: Install a sanitary seal between casing and well cover plate/seal all gaps and <br /> openings. <br /> ❑ Lack of or Inadequate Sampling Tap. <br /> (SJC Well Standards, Section 4.13.—Sampling Tap) <br /> Corrective Action: Install a non-threaded sampling tap between the wellhead and the check valve <br /> or within three (3) feet of the well head. <br /> M Lack of or Inadequate Backflow Prevention. <br /> (SJC Water Well Standards, Section 4.14.—Backflow Prevention) <br /> Corrective Action: Install an approved protective device to prevent backflow and/or back <br /> siphonage into a well. <br /> ❑ Sounding Tube or Air Vent not Sealed. <br /> (SJC Water Well Standards, Section 4.13. —Sounding Tube/Air Vent Pipe) <br /> Corrective Action: Sounding Tube or Fill Pipe-Install a watertight, threaded cap at the upper end <br /> of the pipe. Air Vent-extend pipe 12 inches above with end inverted in a <br /> downward direction and covered with 16-mesh screening. <br /> ❑ Lack of pump permit for well water pump. <br /> (SJC Well Standards, Sec. 2.2—Permitting) <br /> Corrective Action: The owner of the property or the appropriate licensed well or pump contractor <br /> shall obtain a pump permit anytime the sanitary seal on the wellhead is <br /> removed-, or for the installation of a new pump. <br /> If you have any questions, contact: Daria Afonskaia, Registered Environmental Health Specialist (209) 616- <br /> 3035, Please call when work is complete. <br /> oSteve&nShilh, REHS <br /> Program Coordinator <br /> 1868 E. Hazelton Avenue Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />